Literature DB >> 10596216

Utility of postcolumn addition of 2-(2-methoxyethoxy)ethanol, a signal-enhancing modifier, for metabolite screening with liquid chromatography and negative ion electrospray ionization mass spectrometry.

J Yamaguchi1, M Ohmichi, S Jingu, N Ogawa, S Higuchi.   

Abstract

A strategy for highly sensitive metabolite screening by liquid chromatography-electrospray ionization (ESI) mass spectrometry with the negative-ion mode that involves the use of a reversed-phase column in gradient-elution mode and postcolumn addition of 2-(2-methoxyethoxy)ethanol (2-MEE), a novel signal-enhancing modifier, has been described. When a mobile phase of 50 mM ammonium acetate/acetic acid buffer (pH 4.4) at a flow rate of 100 microL/min was employed, poor ESI response of ibuprofen as a model drug, probably due to both the high surface tension of the mobile phase and the ion-suppression effect of acetate anion in the mobile phase, was observed. On the other hand, the postcolumn addition of 2-MEE (50 microL/min) into the mobile phase counteracted the ion suppression as well as the surface tension problem, resulting in approximately 100-fold signal enhancement of the analyte. The metabolite screening of ibuprofen in human urine was subsequently carried out comparing the results with and without postcolumn addition of 2-MEE. The results indicated that the postcolumn addition of 2-MEE dramatically improved the ESI responses of all urinary metabolites detected without affecting the chromatographic separation.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10596216     DOI: 10.1021/ac990664v

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

1.  Buffer loading for counteracting metal salt-induced signal suppression in electrospray ionization.

Authors:  Anthony T Iavarone; Osita A Udekwu; Evan R Williams
Journal:  Anal Chem       Date:  2004-07-15       Impact factor: 6.986

2.  Liquid chromatography electrospray ionization tandem mass spectrometry analysis method for simultaneous detection of trichloroacetic acid, dichloroacetic acid, S-(1,2-dichlorovinyl)glutathione and S-(1,2-dichlorovinyl)-L-cysteine.

Authors:  Sungkyoon Kim; Leonard B Collins; Gunnar Boysen; James A Swenberg; Avram Gold; Louise M Ball; Blair U Bradford; Ivan Rusyn
Journal:  Toxicology       Date:  2009-06-21       Impact factor: 4.221

3.  Ammonium Fluoride as Suitable Additive for HILIC-Based LC-HRMS Metabolomics.

Authors:  Luca Narduzzi; Anne-Lise Royer; Emmanuelle Bichon; Yann Guitton; Corinne Buisson; Bruno Le Bizec; Gaud Dervilly-Pinel
Journal:  Metabolites       Date:  2019-11-27
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.