Literature DB >> 10595890

Biomechanical performance of powder-free examination gloves.

M D Fisher1, V R Reddy, F M Williams, K Y Lin, J G Thacker, R F Edlich.   

Abstract

Biomechanical performance studies were undertaken for powder-free, latex and nitrile examination gloves. Using standardized tests, examination glove performance was judged by measuring glove thickness, glove puncture force, glove tape adhesion force, glove donning force, glove stiffness, and immediate unrecovered stretch. Even though the nitrile examination gloves were thinner than the latex examination gloves, they exhibited a greater puncture resistance. In addition, tape adherence to the N-Dex nitrile glove was the lowest. Moreover, measurements of the handling characteristics of the nitrile examination gloves demonstrated that they are an acceptable alternative to latex examination gloves. While these biomechanical studies demonstrate the superiority of the nitrile examination gloves, clinical glove evaluation is still needed to determine their performance in the health care setting.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10595890     DOI: 10.1016/s0736-4679(99)00133-x

Source DB:  PubMed          Journal:  J Emerg Med        ISSN: 0736-4679            Impact factor:   1.484


  7 in total

1.  Changes in chemical permeation of disposable latex, nitrile, and vinyl gloves exposed to simulated movement.

Authors:  Robert N Phalen; Thi Le; Weng Kee Wong
Journal:  J Occup Environ Hyg       Date:  2014       Impact factor: 2.155

2.  Tensile properties and integrity of clean room and low-modulus disposable nitrile gloves: a comparison of two dissimilar glove types.

Authors:  Robert N Phalen; Weng Kee Wong
Journal:  Ann Occup Hyg       Date:  2011-12-26

3.  Bench Validation of a Handcrafted Prototype Catheter for Intra-gastric Pressure Monitoring.

Authors:  Alberto Federico García; Julián Chica Yantén; Álvaro Ignacio Sánchez; Jose Luis Aldana; Jorge Humberto Mejía; Daniela Burbano; Camilo Salazar
Journal:  World J Surg       Date:  2020-06       Impact factor: 3.352

4.  Common Behaviors and Faults When Doffing Personal Protective Equipment for Patients With Serious Communicable Diseases.

Authors:  Joel M Mumma; Francis T Durso; Lisa M Casanova; Kimberly Erukunuakpor; Colleen S Kraft; Susan M Ray; Andi L Shane; Victoria L Walsh; Puja Y Shah; Craig Zimring; Jennifer DuBose; Jesse T Jacob
Journal:  Clin Infect Dis       Date:  2019-09-13       Impact factor: 9.079

5.  Glove-based sensors for multimodal monitoring of natural sweat.

Authors:  Mallika Bariya; Lu Li; Rahul Ghattamaneni; Christine Heera Ahn; Hnin Yin Yin Nyein; Li-Chia Tai; Ali Javey
Journal:  Sci Adv       Date:  2020-08-28       Impact factor: 14.136

6.  Effect of multiple alcohol-based hand rub applications on the tensile properties of thirteen brands of medical exam nitrile and latex gloves.

Authors:  Pengfei Gao; Matthew Horvatin; George Niezgoda; Robyn Weible; Ronald Shaffer
Journal:  J Occup Environ Hyg       Date:  2016-12       Impact factor: 2.155

7.  Dental professionals' knowledge and behavior towards utilization of gloves: a cross-sectional survey.

Authors:  Arun Suresh Dodamani; Harish Chaitram Jadhav; Mahesh Ravindra Khairnar; Rahul Gaybaro Naik
Journal:  J Prev Med Hyg       Date:  2021-01-14
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.