Literature DB >> 10588284

Analytic characterization of linear accelerator radiosurgery dose distributions for fast optimization.

S L Meeks1, F J Bova, J M Buatti, W A Friedman, B Eyster, L A Kendrick.   

Abstract

Linear accelerator (linac) radiosurgery utilizes non-coplanar arc therapy delivered through circular collimators. Generally, spherically symmetric arc sets are used, resulting in nominally spherical dose distributions. Various treatment planning parameters may be manipulated to provide dose conformation to irregular lesions. Iterative manipulation of these variables can be a difficult and time-consuming task, because (a) understanding the effect of these parameters is complicated and (b) three-dimensional (3D) dose calculations are computationally expensive. This manipulation can be simplified, however, because the prescription isodose surface for all single isocentre distributions can be approximated by conic sections. In this study, the effects of treatment planning parameter manipulation on the dimensions of the treatment isodose surface were determined empirically. These dimensions were then fitted to analytic functions, assuming that the dose distributions were characterized as conic sections. These analytic functions allowed real-time approximation of the 3D isodose surface. Iterative plan optimization, either manual or automated, is achieved more efficiently using this real time approximation of the dose matrix. Subsequent to iterative plan optimization, the analytic function is related back to the appropriate plan parameters, and the dose distribution is determined using conventional dosimetry calculations. This provides a pseudo-inverse approach to radiosurgery optimization, based solely on geometric considerations.

Mesh:

Year:  1999        PMID: 10588284     DOI: 10.1088/0031-9155/44/11/307

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  How to estimate R50% for cranial SRS/SRT cases with overlapping 50% isodose volumes: A proposed system.

Authors:  Dharmin D Desai; Ivan L Cordrey
Journal:  J Appl Clin Med Phys       Date:  2022-05-02       Impact factor: 2.243

2.  A measure of SRS/SRT plan quality: Quantitative limits for intermediate dose spill (R50%) in linac-based delivery.

Authors:  Dharmin D Desai; Ivan L Cordrey; E L Johnson
Journal:  J Appl Clin Med Phys       Date:  2022-03-02       Impact factor: 2.243

3.  A simple knowledge-based tool for stereotactic radiosurgery pre-planning.

Authors:  Daniel S Goldbaum; Justin D Hurley; Russell J Hamilton
Journal:  J Appl Clin Med Phys       Date:  2019-11-19       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.