Literature DB >> 10587634

Miniaturized time-of-flight mass spectrometer for peptide and oligonucleotide analysis.

R J Cotter1, C Fancher, T J Cornish.   

Abstract

A matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometer was developed which uses a novel reflectron composed of a grounded cylinder and an adjustable endcap electrode to provide high-order kinetic energy focusing for a miniaturized mass analyzer. The nearly quadratic potential form of the reflecting field focuses ions desorbed from a source of very small dimensions formed by placing the sample probe within the centered hole of the coaxial dual channel plate detector. At the same time, the depth of the reflectron can be adjusted to accommodate a short drift length between the source/detector and the reflectron. For larger drift lengths, in particular to allow the addition of an XY stage for the analysis of sample arrays, endcap reflectron focusing can be combined with time-delayed ion extraction to achieve good mass resolution. The instrument has been used for the analysis of peptides digested with trypsin or carboxypeptidase, and also small DNA oligomers. Copyright 1999 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10587634     DOI: 10.1002/(SICI)1096-9888(199912)34:12<1368::AID-JMS905>3.0.CO;2-S

Source DB:  PubMed          Journal:  J Mass Spectrom        ISSN: 1076-5174            Impact factor:   1.982


  7 in total

Review 1.  Miniature and Fieldable Mass Spectrometers: Recent Advances.

Authors:  Dalton T Snyder; Christopher J Pulliam; Zheng Ouyang; R Graham Cooks
Journal:  Anal Chem       Date:  2015-10-21       Impact factor: 6.986

2.  Simulations of ion trapping in a micrometer-sized cylindrical ion trap.

Authors:  Daniel E Austin; Dolores Cruz; Matthew G Blain
Journal:  J Am Soc Mass Spectrom       Date:  2006-01-25       Impact factor: 3.109

3.  A Miniaturized Linear Wire Ion Trap with Electron Ionization and Single Photon Ionization Sources.

Authors:  Qinghao Wu; Yuan Tian; Ailin Li; Derek Andrews; Aaron R Hawkins; Daniel E Austin
Journal:  J Am Soc Mass Spectrom       Date:  2017-01-31       Impact factor: 3.109

4.  Toward universal flavivirus identification by mass cataloging.

Authors:  George W Jackson; Roger J McNichols; George E Fox; Richard C Willson
Journal:  J Mol Diagn       Date:  2008-02-07       Impact factor: 5.568

5.  Implementation of DART and DESI ionization on a fieldable mass spectrometer.

Authors:  J Mitchell Wells; Michael J Roth; Adam D Keil; John W Grossenbacher; Dina R Justes; Garth E Patterson; Dennis J Barket
Journal:  J Am Soc Mass Spectrom       Date:  2008-07-18       Impact factor: 3.109

6.  Performance evaluation of a Loeb-Eiber mass filter at 1 Torr.

Authors:  William D Hoffmann; Feng Jin; Randall E Pedder; Christopher Taormina; Glen P Jackson
Journal:  J Am Soc Mass Spectrom       Date:  2014-12-20       Impact factor: 3.109

7.  Development of a Portable Single Photon Ionization-Photoelectron Ionization Time-of-Flight Mass Spectrometer.

Authors:  Yunguang Huang; Jinxu Li; Bin Tang; Liping Zhu; Keyong Hou; Haiyang Li
Journal:  Int J Anal Chem       Date:  2015-10-26       Impact factor: 1.885

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.