Literature DB >> 10584655

Stent placement of gastroenteric anastomoses formed by magnetic compression.

C Cope1, T W Clark, G Ginsberg, P Habecker.   

Abstract

PURPOSE: To evaluate the use of stents for prolonging the patency of gastroenteric anastomoses (GEA) induced by magnet compression.
MATERIALS AND METHODS: Rare earth magnets were inserted perorally and serially in 15 dogs so as to mate across the gastric and jejunal walls. After magnet excretion, the resulting GEA was identified endoscopically, dilated (n = 1), and stented with bare (n = 2) or partially covered (n = 6) flared 10-mm or 12-mm Z stents. The GEA was followed at 2-4-week intervals for patency; malfunctioning shunts were irrigated, or dilated with angioplasty balloons. Gross and histologic examination of the anastomotic tissues was performed in 14 animals.
RESULTS: Magnet pairs were excreted in 5-7 days. Of the 19 magnet placements in 15 animals, stent placement was not possible because of early GEA closure (n = 6), failure to locate (n = 2), pancreatic abscess (n = 1), and magnet perforation with peritonitis (n = 1). Estimated duration of GEA patency was 19 days after balloon dilation, 40-64 days with bare Z stents, and 58-147 days (mean, 90 days) with partially covered Z stents. Shunt function was commonly hindered by bezoars. Stent narrowing or occlusion was caused by tissue overgrowth through bare stents (n = 2), between covered stent struts and through partially detached membrane (n = 2). Serious morbidity (n = 2) was due to malpositioned magnets across the pancreas in one animal and gastric perforation in the other. One dog was euthanized because of unsuspected kidney infection.
CONCLUSION: Partially covered stents significantly extend the anatomic patency rate of magnetic GEA to 7 weeks or more. Functional patency is frequently impaired by bezoars. Ongoing improvements in covered stent design should provide longer-term GEA patency.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10584655     DOI: 10.1016/s1051-0443(99)70248-4

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  9 in total

Review 1.  Compression anastomoses in colorectal surgery: a review.

Authors:  A P Zbar; Y Nir; A Weizman; M Rabau; A Senagore
Journal:  Tech Coloproctol       Date:  2012-04-26       Impact factor: 3.781

2.  Magnetic compression gastrostomy in the rat.

Authors:  Ibrahim Uygun; Mehmet Hanifi Okur; Hasan Cimen; Aysenur Keles; Ozben Yalcin; Hayrettin Ozturk; Selcuk Otcu
Journal:  Pediatr Surg Int       Date:  2012-01-24       Impact factor: 1.827

Review 3.  Endoscopic treatment of gastroparesis.

Authors:  Thomas R McCarty; Tarun Rustagi
Journal:  World J Gastroenterol       Date:  2015-06-14       Impact factor: 5.742

4.  Extrahepatic portacaval shunt via a magnetic compression technique: A cadaveric feasibility study.

Authors:  Xiao-Peng Yan; Wen-Yan Liu; Jia Ma; Jian-Peng Li; Yi Lv
Journal:  World J Gastroenterol       Date:  2015-07-14       Impact factor: 5.742

5.  Magnetic compression anastomosis as a nonsurgical treatment for esophageal atresia.

Authors:  Mario Zaritzky; Ricardo Ben; Gaston I Zylberg; Brian Yampolsky
Journal:  Pediatr Radiol       Date:  2009-06-09

6.  Advanced Roux-en-Y hepaticojejunostomy with magnetic compressive anastomats in obstructive jaundice dog models.

Authors:  Chao Fan; Hongke Zhang; Xiaopeng Yan; Jia Ma; Chunbao Wang; Yi Lv
Journal:  Surg Endosc       Date:  2017-08-04       Impact factor: 4.584

7.  Novel magnetic compression technique for establishment of a canine model of tracheoesophageal fistula.

Authors:  Yi Gao; Rong-Qian Wu; Yi Lv; Xiao-Peng Yan
Journal:  World J Gastroenterol       Date:  2019-08-14       Impact factor: 5.742

8.  Magnetic instrumentation and other applications of magnets in NOTES.

Authors:  Jarek Kobiela; Szymon Grymek; Magdalena Wojanowska; Marek Lubniewski; Wojciech Makarewicz; Sebastian Dobrowolski; Andrzej J Lachiński; Zbigniew Sledziński
Journal:  Wideochir Inne Tech Maloinwazyjne       Date:  2011-11-10       Impact factor: 1.195

9.  Portacaval shunt established in six dogs using magnetic compression technique.

Authors:  Xiaopeng Yan; Chao Fan; Jia Ma; Jianhui Li; Dinghui Dong; Haohua Wang; Feng Ma; Xinglong Zheng; Yi Lv
Journal:  PLoS One       Date:  2013-09-30       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.