Literature DB >> 10582801

A new method for crosstalk correction in simultaneous dual-isotope myocardial imaging with Tl-201 and I-123.

A Tsuji1, A Kojima, M Matsumoto, Y Oyama, S Tomiguchi, T Kira, Y Takagi, O Shimomura, M Takahashi.   

Abstract

We have developed a new method of crosstalk correction in simultaneous dual-isotope imaging with Tl-201 and I-123 by using crosstalk ratios and a blurring filter. Single isotope myocardial studies (10 for Tl-201 and 7 for I-123) were performed with a dual energy window acquisition mode and two low energy general-purpose collimators. Then two planar images acquired with dual energy windows for a Tl-201 line source and an I-123 line source were obtained to measure line spread functions (LSFs) and crosstalk ratios for each image. The line source experiments showed that the LSFs for the Tl-201 imaging window from the single Tl-201 source were very similar to those for the I-123 imaging window from the single Tl-201 source, but the LSFs for the Tl-201 imaging window from the single I-123 source had broad shapes which differed from those for the I-123 imaging window from the single I-123. To obtain accurate I-123 crosstalk images in the Tl-201 imaging window from the I-123 images in the I-123 imaging window, we designed a low-pass blurring filter. In 7 clinical I-123 MIBG studies, I-123 window images processed with this filter became very similar to the Tl-201 window image from the single I-123 source. The method proposed in this study can accurately correct the crosstalk in dual isotope studies with Tl-201 and I-123 and is easily applicable to conventional gamma camera systems with any dual energy window acquisition mode.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10582801     DOI: 10.1007/BF03164870

Source DB:  PubMed          Journal:  Ann Nucl Med        ISSN: 0914-7187            Impact factor:   2.668


  4 in total

1.  Nicorandil affords cardioprotection in patients with acute myocardial infarction treated with primary percutaneous transluminal coronary angioplasty: assessment with thallium-201/iodine-123 BMIPP dual SPECT.

Authors:  S Fukuzawa; S Ozawa; M Inagaki; K Shimada; J Sugioka; K Tateno; M Ueda
Journal:  J Nucl Cardiol       Date:  2000 Sep-Oct       Impact factor: 5.952

2.  Comparative Cardiac Phantom Study Using Tc-99m/I-123 and Tl-201/I-123 Tracers with Cadmium-Zinc-Telluride Detector-Based Single-Photon Emission Computed Tomography.

Authors:  Takanaga Niimi; Mamoru Nanasato; Mitsuo Sugimoto; Hisatoshi Maeda
Journal:  Nucl Med Mol Imaging       Date:  2018-12-12

3.  Crosstalk Reduction Using a Dual Energy Window Scatter Correction in Compton Imaging.

Authors:  Makoto Sakai; Raj Kumar Parajuli; Yoshiki Kubota; Nobuteru Kubo; Mitsutaka Yamaguchi; Yuto Nagao; Naoki Kawachi; Mikiko Kikuchi; Kazuo Arakawa; Mutsumi Tashiro
Journal:  Sensors (Basel)       Date:  2020-04-26       Impact factor: 3.576

4.  Simultaneous multi-nuclide imaging via double-photon coincidence method with parallel hole collimators.

Authors:  Mizuki Uenomachi; Kenji Shimazoe; Kenichiro Ogane; Hiroyuki Takahashi
Journal:  Sci Rep       Date:  2021-06-25       Impact factor: 4.379

  4 in total