Literature DB >> 10561620

Predictive value of fetal scalp blood lactate concentration and pH as markers of neurologic disability.

K Kruger1, B Hallberg, M Blennow, M Kublickas, M Westgren.   

Abstract

OBJECTIVES: We aimed to analyze the predictive value of the fetal scalp blood lactate concentration and pH, especially in regard to outcome variables that are strong predictors of impaired long-term outcome. An additional aim was to establish cutoff lactate levels in fetal scalp blood. STUDY
DESIGN: We conducted a retrospective study of all patients who had fetal scalp blood sampling performed because of an ominous fetal heart rate pattern at Huddinge University Hospital from October 1993 to October 1998. Fetal scalp blood sampling was performed in 1709 patients. The pH and the lactate concentration were determined in fetal scalp blood of 1221 and 814 of these patients, respectively. Outcome variables included pH <7.0 in umbilical artery blood; base deficit >16.0 mmol/L in umbilical artery blood; Apgar scores <7 at 1 minute, <7 at 5 minutes, and <4 at 5 minutes; and hypoxic-ischemic encephalopathy.
RESULTS: Sensitivity and specificity were generally higher in the lactate group than in the pH group, particularly in relation to an Apgar score <4 at 5 minutes and moderate to severe hypoxic-ischemic encephalopathy. In 326 patients the scalp blood lactate concentration and pH value had been obtained at the same time, thus allowing a comparison between these methods. The areas under the receiver operating characteristic curves were significantly higher for the lactate concentration than for the pH value with 2 outcome variables: Apgar score <4 at 5 minutes (P =.033) and moderate to severe hypoxic-ischemic encephalopathy (P =.015).
CONCLUSIONS: Our findings suggest that determination of the lactate concentration in fetal scalp blood is a more sensitive diagnostic tool than is determination of the pH value for predicting either an Apgar score <4 at 5 minutes or moderate to severe hypoxic-ischemic encephalopathy. In previous studies we also showed lactate measurements to be more often successful than pH analysis. Therefore we consider the measurement of lactate in fetal scalp blood to be an attractive alternative to pH analysis, and determination of the lactate concentration in fetal scalp blood seems to be a useful tool for monitoring the condition of the fetus. A suitable cutoff limit for fetal scalp blood lactate concentration as an indicator of fetal asphyxia could be 4.8 mmol/L.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10561620     DOI: 10.1016/s0002-9378(99)70083-9

Source DB:  PubMed          Journal:  Am J Obstet Gynecol        ISSN: 0002-9378            Impact factor:   8.661


  15 in total

1.  Reliability and accuracy of six hand-held blood lactate analysers.

Authors:  Jacinta M Bonaventura; Ken Sharpe; Emma Knight; Kate L Fuller; Rebecca K Tanner; Christopher J Gore
Journal:  J Sports Sci Med       Date:  2015-03-01       Impact factor: 2.988

2.  Umbilical Artery Lactate Correlates with Brain Lactate in Term Infants.

Authors:  Alison G Cahill; George A Macones; Christopher D Smyser; Julia D López; Terrie E Inder; Amit M Mathur
Journal:  Am J Perinatol       Date:  2016-10-27       Impact factor: 1.862

3.  Association between urinary lactate to creatinine ratio and neurodevelopmental outcome in term infants with hypoxic-ischemic encephalopathy.

Authors:  William Oh; Rebecca Perritt; Seetha Shankaran; Matthew Merritts; Edward F Donovan; Richard A Ehrenkranz; T Michael O'Shea; Jon E Tyson; Abbot R Laptook; Abhik Das; Rosemary D Higgins
Journal:  J Pediatr       Date:  2008-05-09       Impact factor: 4.406

4.  Determination of pH or lactate in fetal scalp blood in management of intrapartum fetal distress: randomised controlled multicentre trial.

Authors:  E Wiberg-Itzel; C Lipponer; M Norman; A Herbst; D Prebensen; A Hansson; A-L Bryngelsson; M Christoffersson; M Sennström; U-B Wennerholm; L Nordström
Journal:  BMJ       Date:  2008-05-25

Review 5.  Fetal pulse oximetry for fetal assessment in labour.

Authors:  Christine E East; Lisa Begg; Paul B Colditz; Rosalind Lau
Journal:  Cochrane Database Syst Rev       Date:  2014-10-07

6.  Lactate: creatinine ratio in babies with thin meconium staining of amniotic fluid.

Authors:  Rishi Kant Ojha; Saroj K Singh; Sanjay Batra; V Sreenivas; Jacob M Puliyel
Journal:  BMC Pediatr       Date:  2006-04-20       Impact factor: 2.125

7.  Comparison of a novel computerized analysis program and visual interpretation of cardiotocography.

Authors:  Chen-Yu Chen; Chun Yu; Chia-Chen Chang; Chii-Wann Lin
Journal:  PLoS One       Date:  2014-12-01       Impact factor: 3.240

8.  Infant outcome at four years of age after intrapartum sampling of scalp blood lactate for fetal assessment. A cohort study.

Authors:  Nana Wiberg; Tobias Wirenfeldt Klausen; Tobias Tyrberg; Lennart Nordström; Eva Wiberg-Itzel
Journal:  PLoS One       Date:  2018-03-23       Impact factor: 3.240

9.  Protocol for a randomised controlled trial of fetal scalp blood lactate measurement to reduce caesarean sections during labour: the Flamingo trial [ACTRN12611000172909].

Authors:  Christine E East; Stefan C Kane; Mary-Ann Davey; C Omar Kamlin; Shaun P Brennecke
Journal:  BMC Pregnancy Childbirth       Date:  2015-11-03       Impact factor: 3.007

Review 10.  Sensors for Fetal Hypoxia and Metabolic Acidosis: A Review.

Authors:  Gerard Cummins; Jessica Kremer; Anne Bernassau; Andrew Brown; Helen L Bridle; Holger Schulze; Till T Bachmann; Michael Crichton; Fiona C Denison; Marc P Y Desmulliez
Journal:  Sensors (Basel)       Date:  2018-08-13       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.