Literature DB >> 10556119

Clinical application of the forced oscillation technique for CPAP titration in the sleep apnea/hypopnea syndrome.

J R Badia1, R O Farré, R John Kimoff, E Ballester, L Hernández, M Rotger, D Navajas, J M Montserrat.   

Abstract

We have previously demonstrated that upper airway obstruction in sleep apnea/hypopnea syndrome (SAHS) can be accurately assessed in real-time by measuring respiratory impedance (|Z|) with the forced oscillation technique (FOT). The aims of the present study were: (1) to determine the feasibility of identifying the optimal continuous positive airway pressure (CPAP) for patients with SAHS based on analysis of the |Z| signal during conventional polysomnographic CPAP titration studies; and (2) to evaluate practical issues involved in the application of FOT during CPAP titration. We performed CPAP titration in 28 patients with SAHS during polysomnography (PSG) (14 nap and 14 full overnight studies) using a FOT system applied continuously to obtain an on-line measurement of |Z|. FOT was easily implemented and was well-tolerated by the patients. Optimal CPAP levels were determined both in the conventional manner from the standard PSG titration record and during a separate blinded analysis using the FOT signal alone. The mean conventional versus FOT-based optimal CPAP values were similar for both nap studies (10.6 +/- 0.6 [mean +/- SEM] versus 11.1 +/- 0.6 cm H(2)O, respectively, p = 0. 054) and overnight studies (9.9 +/- 0.7 versus 9.9 +/- 0.6 cm H(2)O, respectively, p = 1.00). Subsequent analysis of the PSG record with the FOT signal incorporated demonstrated that artefacts in the |Z| tracing occurred during mask leak, mouth breathing, and movement during arousal. Such abnormalities were readily identified from the flow tracing. These results indicate that, for adequate interpretation, the tracing and values of respiratory impedance obtained by FOT should be evaluated in conjunction with the flow signal. Continuous FOT-guided CPAP titration is feasible and may be a useful adjunct during manual titration. FOT could also potentially serve as the basis for automated CPAP in SAHS.

Entities:  

Mesh:

Year:  1999        PMID: 10556119     DOI: 10.1164/ajrccm.160.5.9902085

Source DB:  PubMed          Journal:  Am J Respir Crit Care Med        ISSN: 1073-449X            Impact factor:   21.405


  8 in total

1.  Effect of laser-assisted uvulopalatoplasty on oral airway resistance during wakefulness in obstructive sleep apnea syndrome.

Authors:  Ching-Chi Lin; Kuo-Sheng Lee; Ke-Chang Chang; Kun-Ming Wu; Chon-Shin Chou
Journal:  Eur Arch Otorhinolaryngol       Date:  2005-09-15       Impact factor: 2.503

Review 2.  Impulse oscillometry in the evaluation of diseases of the airways in children.

Authors:  Hirsh D Komarow; Ian A Myles; Ashraf Uzzaman; Dean D Metcalfe
Journal:  Ann Allergy Asthma Immunol       Date:  2011-01-06       Impact factor: 6.347

3.  New technologies to detect static and dynamic upper airway obstruction during sleep.

Authors:  J M Montserrat; R Farré; D Navajas
Journal:  Sleep Breath       Date:  2001-12       Impact factor: 2.816

Review 4.  Lung Function Assessment by Impulse Oscillometry in Adults.

Authors:  Noemi Porojan-Suppini; Ovidiu Fira-Mladinescu; Monica Marc; Emanuela Tudorache; Cristian Oancea
Journal:  Ther Clin Risk Manag       Date:  2020-11-26       Impact factor: 2.423

5.  Evaluation of a noninvasive algorithm for differentiation of obstructive and central hypopneas.

Authors:  Winfried J Randerath; Marcel Treml; Christina Priegnitz; Sven Stieglitz; Lars Hagmeyer; Christian Morgenstern
Journal:  Sleep       Date:  2013-03-01       Impact factor: 5.849

6.  Trajectories of Emergent Central Sleep Apnea During CPAP Therapy.

Authors:  Dongquan Liu; Jeff Armitstead; Adam Benjafield; Shiyun Shao; Atul Malhotra; Peter A Cistulli; Jean-Louis Pepin; Holger Woehrle
Journal:  Chest       Date:  2017-06-16       Impact factor: 9.410

7.  Evaluation of forced oscilometry technique's parameters in severe obstructive sleep apnea patients without breathing disorder.

Authors:  Besharat Rahimi; Maryam Edalatifard; Khosro Sadeghniiat Haghighi; Hossein Kazemzadeh
Journal:  J Family Med Prim Care       Date:  2020-03-26

8.  Reliability of home CPAP titration with different automatic CPAP devices.

Authors:  Frédéric Sériès; Julie Plante; Yves Lacasse
Journal:  Respir Res       Date:  2008-07-24
  8 in total