Literature DB >> 10549256

Refrigerated storage improves the stability of the complete blood cell count and automated differential.

B L Wood1, J Andrews, S Miller, D E Sabath.   

Abstract

A CBC count was performed on 113 random patient and 21 control specimens before and after 24-hour room temperature (RT) storage; 98 random patient and 20 control specimens also were analyzed before and after 24 hour 4 degrees C storage. The Cell-Dyn 3500 (Abbott Laboratories, Abbott Park, IL) was used for analysis. RT storage showed a decline in WBC count using the optical but not the impedance method, resulting in a large number of WBC flags. An increase in mean corpuscular volume also was seen for patient specimens. The automated WBC differential showed a decrease in the percentage of neutrophils and an increase in the percentage of lymphocytes, owing primarily to neutrophil degeneration. These changes also were seen in the manual differential to a similar degree. Storage of specimens at 4 degrees C largely prevented all of these changes. The implementation of refrigerated specimen storage is a simple, inexpensive method to improve the accuracy of CBC results for aged specimens on automated hematology analyzers.

Entities:  

Mesh:

Year:  1999        PMID: 10549256     DOI: 10.1093/ajcp/112.5.687

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  8 in total

Review 1.  Common and Novel Markers for Measuring Inflammation and Oxidative Stress Ex Vivo in Research and Clinical Practice-Which to Use Regarding Disease Outcomes?

Authors:  Alain Menzel; Hanen Samouda; Francois Dohet; Suva Loap; Mohammed S Ellulu; Torsten Bohn
Journal:  Antioxidants (Basel)       Date:  2021-03-09

2.  Artifactual changes in Sprague-Dawley rat hematologic parameters after storage of samples at 3 °C and 21 °C.

Authors:  Michelle C Cora; Debra King; Laura J Betz; Ralph Wilson; Greg S Travlos
Journal:  J Am Assoc Lab Anim Sci       Date:  2012       Impact factor: 1.232

3.  Short-Term Stability of Hematologic Parameters in Frozen Whole Blood.

Authors:  Olive Tang; Elizabeth Selvin; Valerie Arends; Amy Saenger
Journal:  J Appl Lab Med       Date:  2019-07-23

4.  Stability of hematological analytes during 48 hours storage at three temperatures using Cell-Dyn hematology analyzer.

Authors:  Ozmen Sevda Unalli; Yesim Ozarda
Journal:  J Med Biochem       Date:  2021-06-05       Impact factor: 3.402

5.  Changes of hematological references depends on storage period and temperature conditions in rats and dogs.

Authors:  Jung-Min Lee; Jin Seok Kang
Journal:  Lab Anim Res       Date:  2016-12-23

6.  Effects of pre-analytical handling on selected canine hematological parameters evaluated by automatic analyzer.

Authors:  Labrini Vasileiou Athanasiou; Zoe Polizopoulou; Maria Rafaela Kalafati; George Ntararas; Vasileios Kontos
Journal:  Vet Res Forum       Date:  2016-12-15       Impact factor: 1.054

7.  Assessment of transient changes in oxygen diffusion of single red blood cells using a microfluidic analytical platform.

Authors:  Kevin Ziyang Chng; Yan Cheng Ng; Bumseok Namgung; Justin Kok Soon Tan; Soyeon Park; Sim Leng Tien; Hwa Liang Leo; Sangho Kim
Journal:  Commun Biol       Date:  2021-03-02

8.  Two-stage, in silico deconvolution of the lymphocyte compartment of the peripheral whole blood transcriptome in the context of acute kidney allograft rejection.

Authors:  Casey P Shannon; Robert Balshaw; Raymond T Ng; Janet E Wilson-McManus; Paul Keown; Robert McMaster; Bruce M McManus; David Landsberg; Nicole M Isbel; Greg Knoll; Scott J Tebbutt
Journal:  PLoS One       Date:  2014-04-14       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.