4D magnetic resonance velocity mapping of blood flow patterns in the aorta in young vs. elderly normal subjects.

H G Bogren1, M H Buonocore.   

Abstract

Four-dimensional magnetic resonance MR velocity mapping was developed to study normal flow patterns in the thoracic aorta using time-resolved cardiac gated three-directional velocity data. Sixteen normal subjects were studied, one young group (average age 31 years) and one group with elderly people (average age 72 years). Blood flowed in a right-handed helix from the ascending aorta to the aortic arch. A straight flow pattern or a left-handed helix was seen in the descending aorta. Blood flow was never parabolic. Blood flowed forward in early systole, retrograde in mid-to-end systole, and forward again in diastole in all subjects as a basic pattern. Continuous retrograde flow over a long distance was not seen, but blood entered a retrograde flow column at various levels. In young people blood passed from the aortic valve to the mid-descending aorta in less than one heartbeat. In people in their sixties it took two heartbeats and in people older than 78 years, it took three heartbeats. The maximum systolic forward velocities were higher in young subjects than in elderly while the retrograde velocities were lower. J. Magn. Reson. Imaging 1999;10:861-869. Copyright 1999 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  1999        PMID: 10548800     DOI: 10.1002/(sici)1522-2586(199911)10:5<861::aid-jmri35>3.0.co;2-e

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  45 in total

1.  In vivo and in vitro validation of aortic flow quantification by time-resolved three-dimensional velocity-encoded MRI.

Authors:  Fabian Rengier; Michael Delles; Roland Unterhinninghofen; Sebastian Ley; Matthias Müller-Eschner; Sasan Partovi; Philipp Geisbüsch; Rüdiger Dillmann; Hans-Ulrich Kauczor; Hendrik von Tengg-Kobligk
Journal:  Int J Cardiovasc Imaging       Date:  2012-02-24       Impact factor: 2.357

2.  Interdependencies of aortic arch secondary flow patterns, geometry, and age analysed by 4-dimensional phase contrast magnetic resonance imaging at 3 Tesla.

Authors:  Alex Frydrychowicz; Alexander Berger; Alejandro Munoz Del Rio; Maximilian F Russe; Jelena Bock; Andreas Harloff; Michael Markl
Journal:  Eur Radiol       Date:  2011-12-30       Impact factor: 5.315

3.  Time-resolved 3D quantitative flow MRI of the major intracranial vessels: initial experience and comparative evaluation at 1.5T and 3.0T in combination with parallel imaging.

Authors:  Roland Bammer; Thomas A Hope; Murat Aksoy; Marcus T Alley
Journal:  Magn Reson Med       Date:  2007-01       Impact factor: 4.668

Review 4.  [MR-based tridirectional flow imaging. Acquisition and 3D analysis of flows in the thoracic aorta].

Authors:  R Unterhinninghofen; S Ley; A Frydrychowicz; M Markl
Journal:  Radiologe       Date:  2007-11       Impact factor: 0.635

Review 5.  [Diagnosing stroke aetiologies. Morphologic and functional analysis of the aorta and carotid arteries by MRI].

Authors:  A Harloff; M Markl; A Frydrychowicz; J Hennig; C Weiller
Journal:  Nervenarzt       Date:  2009-08       Impact factor: 1.214

Review 6.  Intracardiac flow visualization: current status and future directions.

Authors:  Daniel Rodriguez Muñoz; Michael Markl; José Luis Moya Mur; Alex Barker; Covadonga Fernández-Golfín; Patrizio Lancellotti; José Luis Zamorano Gómez
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2013-08-01       Impact factor: 6.875

7.  Dampening of blood-flow pulsatility along the carotid siphon: does form follow function?

Authors:  T Schubert; F Santini; A F Stalder; J Bock; S Meckel; L Bonati; M Markl; S Wetzel
Journal:  AJNR Am J Neuroradiol       Date:  2011-04-07       Impact factor: 3.825

8.  Characterization of the highly nonlinear and anisotropic vascular tissues from experimental inflation data: a validation study toward the use of clinical data for in-vivo modeling and analysis.

Authors:  Kinon Chen; Bahar Fata; Daniel R Einstein
Journal:  Ann Biomed Eng       Date:  2008-07-29       Impact factor: 3.934

9.  Performance Analysis of Gyroscope and Accelerometer Sensors for Seismocardiography-Based Wearable Pre-Ejection Period Estimation.

Authors:  Md Mobashir Hasan Shandhi; Beren Semiz; Sinan Hersek; Nazli Goller; Farrokh Ayazi; Omer T Inan
Journal:  IEEE J Biomed Health Inform       Date:  2019-01-28       Impact factor: 5.772

10.  Four-dimensional, flow-sensitive magnetic resonance imaging of blood flow patterns in thoracic aortic dissections.

Authors:  Christopher J François; Michael Markl; Mark L Schiebler; Eric Niespodzany; Benjamin R Landgraf; Christian Schlensak; Alex Frydrychowicz
Journal:  J Thorac Cardiovasc Surg       Date:  2012-07-26       Impact factor: 5.209

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.