Literature DB >> 10548790

Contrast agent-enhanced, free-breathing, three-dimensional coronary magnetic resonance angiography.

M Stuber1, R M Botnar, P G Danias, M V McConnell, K V Kissinger, E K Yucel, W J Manning.   

Abstract

For free-breathing, high-resolution, three-dimensional coronary magnetic resonance angiography (MRA), the use of intravascular contrast agents may be helpful for contrast enhancement between coronary blood and myocardium. In six patients, 0.1 mmol/kg of the intravascular contrast agent MS-325/AngioMARK was given intravenously followed by double-oblique, free-breathing, three-dimensional inversion-recovery coronary MRA with real-time navigator gating and motion correction. Contrast-enhanced, three-dimensional coronary MRA images were compared with images obtained with a T2 prepulse (T2Prep) without exogenous contrast. The contrast-enhanced images demonstrated a 69% improvement in the contrast-to-noise ratio (6.6 +/- 1.1 vs. 11.1 +/- 2.5; P < 0.01) compared with the T2Prep approach. By using the intravascular agent, extensive portions (> 80 mm) of the native left and right coronary system could be displayed consistently with sub-millimeter in-plane resolution. The intravascular contrast agent, MS-325/AngioMARK, leads to a considerable enhancement of the blood/muscle contrast for coronary MRA compared with T2Prep techniques. The clinical value of the agent remains to be defined in a larger patient series. J. Magn. Reson. Imaging 1999;10:790-799. Copyright 1999 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10548790     DOI: 10.1002/(sici)1522-2586(199911)10:5<790::aid-jmri25>3.0.co;2-i

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  26 in total

1.  Imaging of an aberrant right coronary artery with retrospective respiratory-gated 3D-MR angiography.

Authors:  O M Kalinkin; P K Woodard; P A Ludbrook; F R Gutierrez
Journal:  Int J Cardiovasc Imaging       Date:  2001-02       Impact factor: 2.357

2.  In response to the article by Thomas Wittlinger and co-workers: Magnetic resonance imaging of coronary artery occlusions in the navigator technique.

Authors:  Eike Nagel
Journal:  Int J Cardiovasc Imaging       Date:  2002-02       Impact factor: 2.357

3.  Magnetic resonance imaging for the non-invasive detection of stenosis in coronary artery bypass grafts: clinical reality?

Authors:  E E van der Wall; S E Langerak
Journal:  Int J Cardiovasc Imaging       Date:  2002-12       Impact factor: 2.357

4.  Toward comparability of coronary magnetic resonance angiography: proposal for a standardized quantitative assessment.

Authors:  Martijn S Dirksen; Hildo J Lamb; Rob van der Geest; Albert de Roos
Journal:  Eur Radiol       Date:  2003-08-02       Impact factor: 5.315

Review 5.  Magnetic resonance coronary angiography.

Authors:  Phillip C Yang; Michael V McConnell; Dwight G Nishimura; Bob S Hu
Journal:  Curr Cardiol Rep       Date:  2003-01       Impact factor: 2.931

6.  Magnetic resonance coronary angiography with Vasovist: in-vivo T1 estimation to improve image quality of navigator and breath-hold techniques.

Authors:  Kai Nassenstein; Kai-Uwe Waltering; Sebastian Kelle; Thomas Schlosser; Frank Breuckmann; Stefan Maderwald; Peter Hunold; Eike Nagel; Jörg Barkhausen
Journal:  Eur Radiol       Date:  2007-08-14       Impact factor: 5.315

7.  MRI in the detection of stenosis in coronary artery bypass grafts: are invasive techniques still needed?

Authors:  S E Langerak; E E van der Wall
Journal:  Neth Heart J       Date:  2003-01       Impact factor: 2.380

8.  Improved coronary MR angiography using wideband steady state free precession at 3 tesla with sub-millimeter resolution.

Authors:  Hsu-Lei Lee; Ajit Shankaranarayanan; Gerald M Pohost; Krishna S Nayak
Journal:  J Magn Reson Imaging       Date:  2010-05       Impact factor: 4.813

9.  Accelerated whole-heart coronary MRA using motion-corrected sensitivity encoding with three-dimensional projection reconstruction.

Authors:  Jianing Pang; Behzad Sharif; Reza Arsanjani; Xiaoming Bi; Zhaoyang Fan; Qi Yang; Kuncheng Li; Daniel S Berman; Debiao Li
Journal:  Magn Reson Med       Date:  2014-01-16       Impact factor: 4.668

10.  Recurrence of atrial fibrillation correlates with the extent of post-procedural late gadolinium enhancement: a pilot study.

Authors:  Dana C Peters; John V Wylie; Thomas H Hauser; Reza Nezafat; Yuchi Han; Jeong Joo Woo; Jason Taclas; Kraig V Kissinger; Beth Goddu; Mark E Josephson; Warren J Manning
Journal:  JACC Cardiovasc Imaging       Date:  2009-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.