Literature DB >> 10541084

PACS in sonography: accuracy of interpretation using film compared with monitor display. Picture archiving and communication systems.

B S Hertzberg1, M A Kliewer, E K Paulson, D H Sheafor, K S Freed, J D Bowie, B A Carroll, D H DeLong, R C Nelson.   

Abstract

OBJECTIVE: The goal of this study was to determine the relative accuracy of interpretation of sonography when viewed on a monitor or on film.
MATERIALS AND METHODS: Four radiologists twice interpreted a series of 440 sonograms using the following sequences of display formats for initial and second interpretations: film-film, film-monitor, monitor-film, and monitor-monitor. Reporting discrepancies between the initial and subsequent interpretation were reviewed by an arbitration panel unaware of the display mode. Results were analyzed for differences in error rate attributable to film versus monitor display format, chronology of interpretation, individual observer, and observer seniority.
RESULTS: We found no statistically significant difference in the error rate for film (10.3%) versus monitor display format (14.6%) (p = .09). Likewise, we found no significant differences in the error rates attributable to chronology of interpretation (p = .13), individual observer (p = .54), or observer seniority (p = .87).
CONCLUSION: Interpretative accuracy is similar whether sonograms are interpreted on a monitor or on film.

Mesh:

Year:  1999        PMID: 10541084     DOI: 10.2214/ajr.173.5.10541084

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  3 in total

1.  Comparison of PACS and hard-copy 51-inch radiographs for measuring leg length and deformity.

Authors:  Saurabh Khakharia; Daniel Bigman; Austin T Fragomen; Helene Pavlov; S Robert Rozbruch
Journal:  Clin Orthop Relat Res       Date:  2010-07-13       Impact factor: 4.176

2.  The influence of liquid crystal display (LCD) monitors on observer performance for the detection of nodular lesions on chest radiographs.

Authors:  H Usami; M Ikeda; T Ishigaki; H Fukushima; K Shimamoto
Journal:  Eur Radiol       Date:  2005-11-12       Impact factor: 5.315

3.  ROC analysis for diagnostic accuracy of fracture by using different monitors.

Authors:  Zhigang Liang; Kuncheng Li; Xiaolin Yang; Xiangying Du; Jiabin Liu; Xin Zhao; Xiangdong Qi
Journal:  J Digit Imaging       Date:  2006-09       Impact factor: 4.056

  3 in total