Literature DB >> 10540667

Hemodynamics and wall mechanics after stent placement in swine iliac arteries: comparative results from six stent designs.

P H Rolland1, A B Charifi, C Verrier, H Bodard, A Friggi, P Piquet, G Moulin, J M Bartoli.   

Abstract

PURPOSE: To compare the hemodynamics and wall mechanics of swine iliac arteries after placement of six types of stent.
MATERIALS AND METHODS: Stents were placed in the iliac artery of 18 pigs (three pigs each underwent placement with one of six types of stent); 16 untreated pigs served as control animals. Iliac arterial hemodynamics and wall mechanics were measured 4 days after placement.
RESULTS: Four stents (Palmaz-Schatz, Cordis, Warren, NJ; and Strecker, Cragg, and Symphony, Boston Scientific/Vascular, Natick, Mass) caused decreased pulsatile flow rate in the treated and contralateral iliac arteries; one (Memotherm; Bard, Covington, Ga) caused increased flow pulsatility; and one (Wallstent; Schneider, Plymouth, Minn) had no effect. No compliance mismatching was noted for the Cragg, Symphony, and Memotherm stents, whereas a decrease in compliance was noted for the Palmaz-Schatz, Strecker, and Wallstent designs. The Palmaz-Schatz and Strecker stents caused increased arterial wall rigidity, the Symphony and Wallstent designs had no effect, and the Memotherm and Cragg stents caused decreased wall rigidity. Stents made of stiff metal yielded different early results than did stents made of the less rigid nitinol.
CONCLUSION: Soon after implantation, the six stent designs elicited varying changes in blood flow, arterial compliance, and arterial wall mechanics. Contralateral arterial flow also was affected.

Entities:  

Mesh:

Year:  1999        PMID: 10540667     DOI: 10.1148/radiology.213.1.r99oc26229

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  5 in total

1.  Intravascular laser speckle imaging catheter for the mechanical evaluation of the arterial wall.

Authors:  Zeinab Hajjarian; Jingqun Xi; Farouc A Jaffer; Guillermo J Tearney; Seemantini K Nadkarni
Journal:  J Biomed Opt       Date:  2011-02       Impact factor: 3.170

2.  Minimally invasive vascular techniques.

Authors:  M R Lepore; M Yoselevitz; W C Sternbergh; S R Money
Journal:  Ochsner J       Date:  2000-07

3.  Oversizing of self-expanding stents: influence on the development of neointimal hyperplasia of the carotid artery in a canine model.

Authors:  Eberhard C Kirsch; Mark S Khangure; Philip Morling; Terry J York; William McAuliffe
Journal:  AJNR Am J Neuroradiol       Date:  2002-01       Impact factor: 3.825

4.  Increased artery wall stress post-stenting leads to greater intimal thickening.

Authors:  Lucas H Timmins; Matthew W Miller; Fred J Clubb; James E Moore
Journal:  Lab Invest       Date:  2011-03-28       Impact factor: 5.662

5.  Comparative mechanics of diverse mammalian carotid arteries.

Authors:  David A Prim; Mohamed A Mohamed; Brooks A Lane; Kelley Poblete; Mark A Wierzbicki; Susan M Lessner; Tarek Shazly; John F Eberth
Journal:  PLoS One       Date:  2018-08-10       Impact factor: 3.240

  5 in total