The use of radiographic film for linear accelerator stereotactic radiosurgical dosimetry.

J L Robar1, B G Clark.   

Abstract

The measurement of stereotactic radiosurgical dose distributions requires an integrating, high-resolution dosimeter capable of providing a spatial map of absorbed dose. Although radiographic film is an accessible dosimeter fulfilling these criteria, for larger radiotherapy photon fields the sensitivity of film emulsion exhibits significant dependencies on both depth in phantom and field size. We have examined the variation of film sensitivity over the ranges of depths and field sizes of interest in radiosurgery with a 6 MV photon beam. While for large (20cm x 20cm) fields the potential error in dose due to the variation of the film response with depth reaches 15%, the corresponding maximum error for a 2.5 cm diameter radiosurgical beam is 1.5%. This uncertainty was observed to be comparable in magnitude to that produced by variation in processing conditions (1.1%) and by varying the orientation of the film plane relative to the beam central axis (1.5%). The dependence of emulsion sensitivity on field size has been observed to be negligible for fields ranging in diameter from 1.0 cm to 4.0 cm. The source of the dependence of film sensitivity has been illustrated by using an EGS4 Monte Carlo simulation for large fields to illustrate significant increases in the photon spectrum below 400 keV with depth in phantom. In contrast, relative increase of this low-energy component is negligible for radiosurgical photon fields.

Mesh:

Year:  1999        PMID: 10535631     DOI: 10.1118/1.598730

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Quantitative megavoltage radiation therapy dosimetry using the storage phosphor KCl: Eu2+.

Authors:  Zhaohui Han; Joseph P Driewer; Yuanshui Zheng; Daniel A Low; H Harold Li
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

2.  The use of extended dose range film for dosimetric calibration of a scanning liquid-filled ionization chamber electronic portal imaging device.

Authors:  Mohammad Mohammadi; Eva Bezak; Paul Reich
Journal:  J Appl Clin Med Phys       Date:  2006-05-15       Impact factor: 2.102

3.  Dosimetric comparison of extended dose range film with ionization measurements in water and lung equivalent heterogeneous media exposed to megavoltage photons.

Authors:  Paule M Charland; Indrin J Chetty; Shigeru Yokoyama; Benedick A Fraass
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.