Rate of pull-out strength gain of dual-etched titanium implants: a comparative study in rabbits.

D Baker1, R M London, R O'Neal.   

Abstract

The purpose of this study was to investigate the rate of pull-out strength gain of an etched titanium implant surface. Rabbit tibiae were used to compare machined titanium and proprietary dual-etched titanium implants. Two custom cylindric implants (3 mm in diameter and 4 mm in length) were placed in each right anteromedial tibia in 31 rabbits. At weeks 1, 2, 3, 4, 5, and 8, the implants in 5 rabbits were subjected to failure shear loading in a pull-out test. For shear failure testing, each tibial segment was mounted in a precision alignment jig, and an Instron pull-out test was performed on each implant. Beginning at week 3, there was a statistically significant difference (P < .01) between the dual-etched and the machined implants. There was a significant increase in strength for dual-etched implants between week 5 and week 8, while the machined implants did not show an increase during this time interval. The etched implants maintained a significantly greater pull-out strength for the remainder of the study, with a 3.2-fold greater mean strength at 8 weeks, equivalent to 6 months in humans. At 3 weeks, the etched implant's strength exceeded the strength that the machined implant had achieved at 8 weeks. In short-term healing in the rabbit tibia, the dual-etched surface demonstrated a more rapid rate of pull-out strength gain than the machined surface and remained significantly stronger throughout the 8 weeks of the study.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10531744

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  7 in total

1.  Intelligent modeling and optimization of titanium surface etching for dental implant application.

Authors:  Seyyed Mohamad Sadati Tilebon; Seyed Amirhossein Emamian; Hosseinali Ramezanpour; Hashem Yousefi; Mutlu Özcan; Seyed Morteza Naghib; Yasser Zare; Kyong Yop Rhee
Journal:  Sci Rep       Date:  2022-05-03       Impact factor: 4.996

2.  Tensile force testing of optimized coin-shaped titanium implant attachment kinetics in the rabbit tibiae.

Authors:  Hans Jacob Rønold; Jan Eirik Ellingsen; Ståle Petter Lyngstadaas
Journal:  J Mater Sci Mater Med       Date:  2003-10       Impact factor: 3.896

3.  Bone-bonding properties of Ti metal subjected to acid and heat treatments.

Authors:  Toshiyuki Kawai; Mitsuru Takemoto; Shunsuke Fujibayashi; Masashi Neo; Haruhiko Akiyama; Seiji Yamaguchi; Deepak K Pattanayak; Tomiharu Matsushita; Takashi Nakamura; Tadashi Kokubo
Journal:  J Mater Sci Mater Med       Date:  2012-09-05       Impact factor: 3.896

4.  Application of laser-induced bone therapy by carbon dioxide laser irradiation in implant therapy.

Authors:  Takahiro Naka; Satoshi Yokose
Journal:  Int J Dent       Date:  2012-02-06

5.  Biological Safety Evaluation and Surface Modification of Biocompatible Ti-15Zr-4Nb Alloy.

Authors:  Yoshimitsu Okazaki; Shin-Ichi Katsuda
Journal:  Materials (Basel)       Date:  2021-02-04       Impact factor: 3.623

6.  Evaluation of the effects of different surface configurations on stability of miniscrews.

Authors:  Tolga Topcuoglu; A Altuğ Bicakci; M Cihat Avunduk; Z Deniz Sahin Inan
Journal:  ScientificWorldJournal       Date:  2013-07-01

7.  Effect of intermittent administration of teriparatide on the mechanical and histological changes in bone grafted with β-tricalcium phosphate using a rabbit bone defect model.

Authors:  Jun Komatsu; Nana Nagura; Hideaki Iwase; Mamoru Igarashi; Osamu Ohbayashi; Isao Nagaoka; Kazuo Kaneko
Journal:  Exp Ther Med       Date:  2017-11-01       Impact factor: 2.447

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.