Literature DB >> 10531741

A histometric comparison of smooth and rough titanium implants in human low-density jawbone.

P Trisi1, W Rao, A Rebaudi.   

Abstract

The aim of this investigation was to conduct a comparative histometric analysis of bone-implant interface between a rough titanium surface and smooth implants in low-density human jawbone after 3, 6, and 12 months of submerged, undisturbed healing. Six adult volunteer patients undergoing standard implant placement were enrolled in this project. Each patient received 1 smooth and 1 rough implant. After 3, 6, and 12 months, the implants were harvested for histometric analysis. The values of bone-implant contact were the following: 3 months smooth 6.2%, 3 months rough 58.9%, 6 months smooth 3.55%, 6 months rough 72.9%, 12 months smooth 6.7%, and 12 months rough 76.75%. The results showed that in low-density bone the rough surface dramatically enhanced the amount of bone-to-implant contact. Because of the small number of implants examined, definite conclusions cannot be drawn, even though the statistical analysis showed significant differences between the smooth and rough groups (P = .0129; F = 76.065). Nevertheless, a trend was evident in these observations: while a rough implant surface may enhance the rate of osseointegration, it is not able to significantly change the bone density, and an implant placed low-density bone is at a higher risk of failure when occlusal loading begins.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10531741

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  5 in total

1.  Preparation of chitosan-tannic acid coating and its anti-osteoclast and antibacterial activities in titanium implants.

Authors:  Bo Liao; Cheng Xu; Zhenglun Wang; Wei Li; Xinyu Liu; Dong Lu
Journal:  J Bone Miner Metab       Date:  2022-02-07       Impact factor: 2.626

2.  The effect of erbium-doped: yttrium, aluminium and garnet laser irradiation on the surface microstructure and roughness of double acid-etched implants.

Authors:  Ji-Hyun Kim; Yeek Herr; Jong-Hyuk Chung; Seung-Il Shin; Young-Hyuk Kwon
Journal:  J Periodontal Implant Sci       Date:  2011-10-31       Impact factor: 2.614

3.  Correlation between cortical bone thickness at mini-implant insertion sites and age of patient.

Authors:  Anna Carolina Teixeira Centeno; Caroline Kolling Fensterseifer; Vitória de Oliveira Chami; Eduardo Silveira Ferreira; Mariana Marquezan; Vilmar Antônio Ferrazzo
Journal:  Dental Press J Orthod       Date:  2022-02-28

4.  Effects of cortical bone thickness and trabecular bone density on primary stability of orthodontic mini-implants.

Authors:  Chin-Yun Pan; Pao-Hsin Liu; Yu-Chuan Tseng; Szu-Ting Chou; Chao-Yi Wu; Hong-Po Chang
Journal:  J Dent Sci       Date:  2019-07-20       Impact factor: 2.080

Review 5.  Does cortical thickness influence the primary stability of miniscrews?: A systematic review and meta-analysis.

Authors:  Mariana Marquezan; Cláudia Trindade Mattos; Eduardo Franzotti Sant'Anna; Margareth Maria Gomes de Souza; Lucianne Cople Maia
Journal:  Angle Orthod       Date:  2014-04-02       Impact factor: 2.079

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.