Literature DB >> 10527216

Reproducibility of surface EMG variables and peak torque during three sets of ten dynamic contractions.

B Larsson1, B Månsson, C Karlberg, P Syvertsson, J Elert, B Gerdle.   

Abstract

The interpretation of the electromyogram (EMG) of dynamic contractions might be difficult because the movement per se introduces additional factors that could affect its characteristics. There is a lack of studies concerning the reproducibility of surface EMG registrations during dynamic contractions. The aim was to investigate the during-the-day reproducibility (using intra-class correlation; ICC) of the peak torque (PT) and the EMG variables (without removing the electrodes) of dynamic contractions. Ten healthy subjects performed three sets of 10 dynamic maximum right-knee extensions with a one-hour interval in between, using an isokinetic dynamometer and the PT was determined. EMG signals were recorded from the right vastus lateralis, rectus femoris and vastus medialis muscles using surface electrodes and the mean frequency of the power spectrum (MNF [Hz]) and the signal amplitude (RMS [microV]), were computed. The ability to relax in-between the maximum extensions was calculated as a ratio of the RMS during the passive flexion phase and the RMS during the active extension phase of each contraction cycle: the signal amplitude ratio (SAR). Both PT (ICC = 0.99) and RMS (ICC = 0.83-0.98) had good reproducibility. The reproducibility of MNF was good for all muscles when the mean of contraction nos.: 1-10 was used. Vastus lateralis had the highest ICC among the three muscles. The reproducibility of SAR was generally poor (ICC < 0.60). The present study showed good reproducibility for common EMG variables (MNF and RMS) obtained during maximum isokinetic contractions.

Mesh:

Year:  1999        PMID: 10527216     DOI: 10.1016/s1050-6411(99)00006-1

Source DB:  PubMed          Journal:  J Electromyogr Kinesiol        ISSN: 1050-6411            Impact factor:   2.368


  6 in total

1.  Motor learning in a complex balance task and associated neuroplasticity: a comparison between endurance athletes and nonathletes.

Authors:  Oliver Seidel; Daniel Carius; Rouven Kenville; Patrick Ragert
Journal:  J Neurophysiol       Date:  2017-06-28       Impact factor: 2.714

2.  Growth hormone substitution titrated to obtain IGF-I levels in the physiological range in hypopituitary adults: effects upon dynamic strength, endurance and EMG.

Authors:  Bertil Ekman; Björn Gerdle; Hans J Arnqvist
Journal:  Eur J Appl Physiol       Date:  2003-07-26       Impact factor: 3.078

3.  Comparison of Two Different Modes of Active Recovery on Muscles Performance after Fatiguing Exercise in Mountain Canoeist and Football Players.

Authors:  Anna Mika; Łukasz Oleksy; Renata Kielnar; Ewa Wodka-Natkaniec; Magdalena Twardowska; Kamil Kamiński; Zbigniew Małek
Journal:  PLoS One       Date:  2016-10-05       Impact factor: 3.240

4.  The Influence of Plantar Short Foot Muscle Exercises on the Lower Extremity Muscle Strength and Power in Proximal Segments of the Kinematic Chain in Long-Distance Runners.

Authors:  Iwona Sulowska; Anna Mika; Łukasz Oleksy; Artur Stolarczyk
Journal:  Biomed Res Int       Date:  2019-01-02       Impact factor: 3.411

5.  Reliability of Vibroarthrography to Assess Knee Joint Sounds in Motion.

Authors:  Kristin Kalo; Daniel Niederer; Rainer Sus; Keywan Sohrabi; Volker Groß; Lutz Vogt
Journal:  Sensors (Basel)       Date:  2020-04-02       Impact factor: 3.576

Review 6.  EMG-Centered Multisensory Based Technologies for Pattern Recognition in Rehabilitation: State of the Art and Challenges.

Authors:  Chaoming Fang; Bowei He; Yixuan Wang; Jin Cao; Shuo Gao
Journal:  Biosensors (Basel)       Date:  2020-07-26
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.