Literature DB >> 10517487

Elasticity and fracture strain of whole blood clots.

P Riha1, X Wang, R Liao, J F Stoltz.   

Abstract

The measurement of clot elasticity and fracture strain is carried out using a rotational rheometer with a controlled stress system. The elasticity is quantified by a shear elastic modulus and fracture strain by a critical strain (deformation) when the clot begins to break up. The results indicate a decrease of elasticity and increase of fracture strain of the clot with increasing hematocrit. Moreover, the elastic modulus of the clot is not constant but increasing with deformation.

Entities:  

Mesh:

Year:  1999        PMID: 10517487

Source DB:  PubMed          Journal:  Clin Hemorheol Microcirc        ISSN: 1386-0291            Impact factor:   2.375


  13 in total

1.  Towards the limit of quantifying low-amplitude strains on bone and in coagulum around immediately loaded oral implants in extraction sockets.

Authors:  Murat Cavit Cehreli; Ayhan Comert; Murat Akkocaoglu; Ibrahim Tekdemir; Kivanc Akca
Journal:  Med Biol Eng Comput       Date:  2006-03       Impact factor: 2.602

2.  Molecular dynamics simulations indicate that deoxyhemoglobin, oxyhemoglobin, carboxyhemoglobin, and glycated hemoglobin under compression and shear exhibit an anisotropic mechanical behavior.

Authors:  Sumith Yesudasan; Xianqiao Wang; Rodney D Averett
Journal:  J Biomol Struct Dyn       Date:  2017-05-22

3.  Fibrin Networks Support Recurring Mechanical Loads by Adapting their Structure across Multiple Scales.

Authors:  Nicholas A Kurniawan; Bart E Vos; Andreas Biebricher; Gijs J L Wuite; Erwin J G Peterman; Gijsje H Koenderink
Journal:  Biophys J       Date:  2016-09-06       Impact factor: 4.033

4.  Investigating the Mechanical Behavior of Clot Analogues Through Experimental and Computational Analysis.

Authors:  Sarah Johnson; Ray McCarthy; Michael Gilvarry; Peter E McHugh; J Patrick McGarry
Journal:  Ann Biomed Eng       Date:  2020-07-20       Impact factor: 3.934

5.  Effect of clot aging and cholesterol content on ultrasound-assisted thrombolysis.

Authors:  Yufeng Zhou; Suresh Kanna Murugappan; Vijay Kumar Sharma
Journal:  Transl Stroke Res       Date:  2014-02-03       Impact factor: 6.829

Review 6.  Fibrin mechanical properties and their structural origins.

Authors:  Rustem I Litvinov; John W Weisel
Journal:  Matrix Biol       Date:  2016-08-20       Impact factor: 11.583

7.  A Fluid-Structure Interaction Analysis of Blood Clot Motion in a Branch of Pulmonary Arteries.

Authors:  Fateme Mirakhorli; Bahman Vahidi; Marzieh Pazouki; Pouria Talebi Barmi
Journal:  Cardiovasc Eng Technol       Date:  2022-07-05       Impact factor: 2.495

8.  Optical Thromboelastography to evaluate whole blood coagulation.

Authors:  Zeinab Hajjarian; Markandey M Tripathi; Seemantini K Nadkarni
Journal:  J Biophotonics       Date:  2014-04-03       Impact factor: 3.207

9.  Evaluating the viscoelastic properties of tissue from laser speckle fluctuations.

Authors:  Zeinab Hajjarian; Seemantini K Nadkarni
Journal:  Sci Rep       Date:  2012-03-16       Impact factor: 4.379

10.  Limitations of using synthetic blood clots for measuring in vitro clot capture efficiency of inferior vena cava filters.

Authors:  Ronald A Robinson; Luke H Herbertson; Srilekha Sarkar Das; Richard A Malinauskas; William F Pritchard; Laurence W Grossman
Journal:  Med Devices (Auckl)       Date:  2013-05-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.