Literature DB >> 10513973

Use of the Hoffman 2 compact external fixator in the treatment of redisplaced unstable distal radial fractures.

M M McQueen1, D Simpson, C M Court-Brown.   

Abstract

The aim of this study was to examine the use of a new joint sparing external fixation device for unstable redisplaced fractures of the distal radius. Participants were twenty consecutive patients with unstable redisplaced fractures of the distal radius with sufficient space in the distal fragment to allow use of a nonbridging technique. The patients had to be capable of cooperating with functional outcome measures. All patients underwent closed nonbridging external fixation of the distal radius using the Hoffman 2 compact external fixator. The main outcome measures were radiological determinations of dorsal angle, radial shortening, and carpal alignment; measurements of mass grip strength and range of movement; and rate of complications. Volar tilt was successfully regained and maintained (mean 4 degrees) at final review. Radial shortening was a mean of one millimeter at final review. Nineteen of twenty patients regained normal carpal alignment. Grip strength returned to a mean of 74 percent of the opposite (normal) side in the whole group and 88 percent in those who completed review for the longest periods. Ranges of movement were restored to around 80 percent, except flexion (66 percent). The rate of major complications was 15 percent. We conclude that nonbridging external fixation using the Hoffman 2 compact device reliably restores and maintains volar tilt and radial length after re-reduction of unstable fractures of the distal radius. Functional outcome and complications are comparable with findings in previous reports.

Entities:  

Mesh:

Year:  1999        PMID: 10513973     DOI: 10.1097/00005131-199909000-00007

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  4 in total

1.  Nonbridging external fixation for fractures of the distal radius.

Authors:  Drew A Bednar; Hamad Al-Harran
Journal:  Can J Surg       Date:  2004-12       Impact factor: 2.089

2.  Efficacy of different fixation devices in maintaining an initial reduction for surgically managed distal radius fractures.

Authors:  Loren Geller; Mitchell Bernstein; Alberto Carli; Greg Berry; Rudy Reindl; Edward Harvey
Journal:  Can J Surg       Date:  2009-10       Impact factor: 2.089

3.  The Unstable Distal Radius Fracture-How Do We Define It? A Systematic Review.

Authors:  Monique M J Walenkamp; Lara M Vos; Simon D Strackee; J Carel Goslings; Niels W L Schep
Journal:  J Wrist Surg       Date:  2015-11

4.  External fixation of fractures of the distal radius: a randomized comparison of the Hoffman compact II non-bridging fixator and the Dynawrist fixator in 75 patients followed for 1 year.

Authors:  Yngvar Krukhaug; Stein Ugland; Stein A Lie; Leiv M Hove
Journal:  Acta Orthop       Date:  2009-02       Impact factor: 3.717

  4 in total