Low-profile versus conventional metacarpal plating systems: a comparison of construct stiffness and strength.

K J Fischer1, J A Bastidas, D A Provenzano, M M Tomaino.   

Abstract

Smaller, lower-profile plates for metacarpal fixation may have the potential to reduce extensor tendon irritation and adhesions, but their sufficiency for stabilizing metacarpal fractures has not been studied. We investigated the relative stiffness and strength of low-profile and conventional plating systems. For apex dorsal bending (bending closed), no plates broke or had notable plastic deformation. The conventional plates exhibited higher overall bending rigidity than all other plates, but had a lower maximum bending moment than the smaller plates. In apex volar bending (bending open) and torsion, the conventional plates were remarkably more rigid and developed remarkably higher torque. In vivo metacarpal loads are primarily apex dorsal bending, and all plates performed well in this mode. Thus, the smaller, low-profile plates may be sufficient for metacarpal fixation, although patient compliance and the use of supplemental stabilization with a cast or splint should be considered.

Entities:  

Mesh:

Year:  1999        PMID: 10509270     DOI: 10.1053/jhsu.1999.0928

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  6 in total

1.  Biomechanical evaluation of metacarpal fracture fixation: application of a 90° internal fixation model.

Authors:  Andrew J Watt; Randal P Ching; Jerry I Huang
Journal:  Hand (N Y)       Date:  2015-03

2.  Minifragment screw fixation of oblique metacarpal fractures: a biomechanical analysis of screw types and techniques.

Authors:  Frank A Liporace; Tosca Kinchelow; Salil Gupta; Erik N Kubiak; Matthew McDonnell
Journal:  Hand (N Y)       Date:  2008-08-29

3.  Complications of Low-Profile Plate Fixation of Phalanx Fractures.

Authors:  Evan M Guerrero; Rita E Baumgartner; Andrew E Federer; Suhail K Mithani; David S Ruch; Marc J Richard
Journal:  Hand (N Y)       Date:  2019-06-17

4.  A biomechanical analysis of plate fixation using unicortical and bicortical screws in transverse metacarpal fracture models subjected to 4-point bending and dynamical bending test.

Authors:  Eirini Liodaki; Robert Wendlandt; Klaus Waizner; Brigitte E Schopp; Peter Mailänder; Felix Stang
Journal:  Medicine (Baltimore)       Date:  2017-07       Impact factor: 1.889

5.  The Effect of Strontium Ranelate on Fracture Healing: An Animal Study.

Authors:  Ourania I Koukou; Lampros D Pappas; Pelagia Chloropoulou; Maria A Kouroupi; Konstantinos I Koukos; Georgia Karpathiou; Antonios A Galanos; Georgios I Drosos; Evaggelos Magnisalis; Alexandra N Giatromanolaki; Dionysios Alexandros Verettas
Journal:  Biomed Res Int       Date:  2020-11-24       Impact factor: 3.411

6.  Long-Term Functional Results of Intra- and Extra-Articular Hand Fractures Treatment With Titanium Miniature Plates and Screws With Minimum Follow-Up of 24 Months.

Authors:  Sokratis Varitimidis; Zoe Dailiana; Dimitrios Agorastakis; Apostolos Fyllos; Aristeidis Zibis; Michael Hantes; Konstantinos Malizos
Journal:  Cureus       Date:  2021-06-04