Literature DB >> 10506369

[Trans-articular screw fixation of C1/C2 in atlanto-axial instability. Comparison between percutaneous and open procedures].

M Blauth1, M Richter, U Lange.   

Abstract

For posttraumatic atlantoaxial instabilities posterior transarticular screw fixation according to Magerl represents the treatment of choice. In order to be able to insert the screws steep enough the soft tissues of the neck have to be dissected down to C7. Several authors therefore described a percutaneous technique. We analysed 30 patients with a sagittal atlantoaxial instability treated with one of both methods between the years 1995 and 1998 to detect any differences of either technique. In 19 cases we used a modified percutaneous technique with special instruments as has been published by McGuire and Harkey. On lateral plain films the angle between the screws and the lower endplate of C2 was measured. 6 to 24 months after the accident 26 patients could be seen clinically and controlled radiologically, 4 patients had died in the meanwhile. The angle of the screws were significantly different with 10 degrees (percutaneous group 73.9 degrees, open group 63.9 degrees, p = 0.001). Time needed for the operative procedure averaged 35 minutes shorter with the cannulated technique (93 to 128 minutes, p = 0.05). All posterior fusions had healed radiologically. Active motion of the c-spine was restricted in both groups equally. We checked subjective criteria concerning pain and function with a visual analog scale and a special score. With these instruments advantages for the percutaneous procedure could be found (freedom of pain 43 points (percutaneous) versus 39 points (open), p = 0.05). We conclude that the soft tissue preserving percutaneous technique of screw application for C1/C2 posterior fusion allows for a better and easier placement of screws. It also leads to a shorter operating time and better subjective results. The method offers particularly advantages in cases where only a temporary stabilization of the C1/C2 complex without a regular fusion is needed.

Entities:  

Mesh:

Year:  1999        PMID: 10506369     DOI: 10.1007/s001320050396

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  8 in total

1.  Accuracy of 3D fluoroscopy-navigated anterior transpedicular screw insertion in the cervical spine: an experimental study.

Authors:  Jan Bredow; Carolin Meyer; Max Joseph Scheyerer; Florian Siedek; Lars Peter Müller; Peer Eysel; Gregor Stein
Journal:  Eur Spine J       Date:  2016-01-25       Impact factor: 3.134

2.  Transarticular screw fixation for atlantoaxial instability - modified Magerl's technique in 38 patients.

Authors:  Raj Bahadur; Tarun Goyal; Saravdeep S Dhatt; Sujit K Tripathy
Journal:  J Orthop Surg Res       Date:  2010-11-22       Impact factor: 2.359

3.  The accuracy of 3D fluoroscopy-navigated screw insertion in the upper and subaxial cervical spine.

Authors:  J Bredow; J Oppermann; B Kraus; P Schiller; G Schiffer; R Sobottke; P Eysel; T Koy
Journal:  Eur Spine J       Date:  2015-04-30       Impact factor: 3.134

4.  A biomechanical rationale for C1-ring osteosynthesis as treatment for displaced Jefferson burst fractures with incompetency of the transverse atlantal ligament.

Authors:  Heiko Koller; Herbert Resch; Mark Tauber; Juliane Zenner; Peter Augat; Rainer Penzkofer; Frank Acosta; Klaus Kolb; Anton Kathrein; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2010-04-13       Impact factor: 3.134

5.  [Transarticular C1-C2 screw fixation: results of unstable odontoid fractures and pseudarthrosis in the elderly].

Authors:  A Kaminski; A Gstrein; G Muhr; E J Müller
Journal:  Unfallchirurg       Date:  2008-03       Impact factor: 1.000

6.  C2-fractures: part I. Quantitative morphology of the C2 vertebra is a prerequisite for the radiographic assessment of posttraumatic C2-alignment and the investigation of clinical outcomes.

Authors:  Heiko Koller; Frank Acosta; Mark Tauber; Elisabeth Komarek; Michael Fox; Mido Moursy; Wolfgang Hitzl; Herbert Resch
Journal:  Eur Spine J       Date:  2009-02-19       Impact factor: 3.134

7.  C2-fractures: part II. A morphometrical analysis of computerized atlantoaxial motion, anatomical alignment and related clinical outcomes.

Authors:  Heiko Koller; Frank Acosta; Rosemarie Forstner; Juliane Zenner; Herbert Resch; Mark Tauber; Stefan Lederer; Alexander Auffarth; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2009-02-18       Impact factor: 3.134

8.  Posterior cervical fixation with a nitinol shape memory loop for primary surgical stabilization of atlantoaxial instability: a preliminary report.

Authors:  Duk-Gyu Kim; Jong-Pil Eun; Jung-Soo Park
Journal:  J Korean Neurosurg Soc       Date:  2012-07-31
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.