Literature DB >> 10504094

Modeling and optimization of rotational C-arm stereoscopic X-ray angiography.

A S Talukdar1, D L Wilson.   

Abstract

Stereoscopy can be an effective method for obtaining three-dimensional (3-D) spatial information from two-dimensional (2-D) projection X-ray images, without the need for tomographic reconstruction. This much-needed information is missed in many X-ray diagnostic and interventional procedures, such as the treatment of vascular aneurysms. Fast C-arm X-ray systems can obtain multiple angle sequences of stereoscopic image pairs from a single contrast injection and a single breath hold. To advance this solution, we developed a model of stereo angiography, performed perception experiments and related results to optimal acquisition. The model described horizontal disparity for the C-arm geometry that agreed very well with measurements from a geometric phantom. The perceptual accommodation-convergence conflict and geometry limited the effective stereoscopic field of view (SFOV). For a typical large image intensifier system, it was 28 cm x 31 cm at the center of rotation (COR). In the model, blurring from finite focal-spot size and C-arm motion reduced depth resolution on the digital display. Near the COR, the predicted depth resolution was 3-11 mm for a viewing angle of 7 degrees , which agreed favorably with results from recently published studies. The model also described how acquisition parameters affected spatial warping of curves of equal apparent depth. Pincushioning and the difference between the acquisition and display geometry were found to introduce additional distortions to stereo displays. Preference studies on X-ray angiograms indicated that the ideal viewing angle should be small (1-2 degrees), which agreed with some previously published work. Perceptual studies indicated that stereo angiograms should have high artery contrast and that digital processing to increase contrast improved stereopsis. Digital subtraction angiograms, with different motion errors between the left and right-eye views, gave artifacts that confused stereopsis. The addition of background to subtracted images reduced this effect and provided other features for improved depth perception. Using the modeling results and typical clinical angiography requirements, we recommend acquisition protocols and engineering specifications that are achievable on current high-end systems.

Entities:  

Mesh:

Year:  1999        PMID: 10504094     DOI: 10.1109/42.790460

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  5 in total

Review 1.  Advances in homology protein structure modeling.

Authors:  Zhexin Xiang
Journal:  Curr Protein Pept Sci       Date:  2006-06       Impact factor: 3.272

2.  Accurate micro-computed tomography imaging of pore spaces in collagen-based scaffold.

Authors:  Jan Zidek; Lucy Vojtova; A M Abdel-Mohsen; Jiri Chmelik; Tomas Zikmund; Jana Brtnikova; Roman Jakubicek; Lukas Zubal; Jiri Jan; Jozef Kaiser
Journal:  J Mater Sci Mater Med       Date:  2016-05-06       Impact factor: 3.896

3.  Calcaneal osteotomy preoperative planning system with 3D full-sized computer-assisted technology.

Authors:  Yi-Jiun Chou; Shuh-Ping Sun; Hsin-Hua Liu
Journal:  J Med Syst       Date:  2010-03-30       Impact factor: 4.460

4.  Investigation of the effect of UV-B light on Arabidopsis MYB4 (AtMYB4) transcription factor stability and detection of a putative MYB4-binding motif in the promoter proximal region of AtMYB4.

Authors:  Mehali Mitra; Puja Agarwal; Anurima Kundu; Victor Banerjee; Sujit Roy
Journal:  PLoS One       Date:  2019-08-08       Impact factor: 3.240

5.  Homology modeling a fast tool for drug discovery: current perspectives.

Authors:  V K Vyas; R D Ukawala; M Ghate; C Chintha
Journal:  Indian J Pharm Sci       Date:  2012-01       Impact factor: 0.975

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.