Quantitative optical densitometry with scanning-laser film digitizers.

J F Dempsey1, D A Low, A S Kirov, J F Williamson.   

Abstract

A new process for eliminating two types of artifacts inherent in commercially available transmission scanning-laser film digitizers is presented. The first kind of artifact results in nonreproducible interference-pattern fluctuations as large as 7%. The second kind results in spreading of transmitted light from low-to-high optical density (OD) in regions with rapidly varying ODs, producing errors as large as 50%. These OD artifacts cause the loss of precision for films with low-OD regions (first type) and the loss of accuracy for films with regions of high-OD near high-OD gradients (second type). Test radiochromic films, produced by uniform exposure to a 6 MV photon beam and a high dose rate 192Ir brachytherapy source, along with test radiographic films were used to characterize the artifacts of a commercially available scanning-laser film digitizer. The interference-pattern artifact was eliminated by digitizing the films on a masked diffusing ground-glass scanning bed. The light-transmission artifact was eliminated through discrete-fast-Fourier-transform (DFFT) deconvolution of transmission profiles with measured digitizer line-spread functions. Obtaining precise OD distributions after the DFFT deconvolution required prior removal of the interference-pattern artifact and application of a low-pass Wiener noise filter. Light-transmission artifacts are particularly significant for applications requiring measurement of high-gradient OD distributions, such as brachytherapy or conformal photon-beam film dosimetry and quantitation of two-dimensional electrophoresis gels. Errors as large as 15%-35% occur in OD distributions representative of these applications. The data collection and correction process developed in this study successfully removes these artifacts.

Mesh:

Year:  1999        PMID: 10501072     DOI: 10.1118/1.598664

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  2 in total

1.  Quantitative analysis of DNA array autoradiographs.

Authors:  C A Pelizzari; N N Khodarev; N Gupta; D P Calvin; R R Weichselbaum
Journal:  Nucleic Acids Res       Date:  2000-11-15       Impact factor: 16.971

2.  Measurement verification of dose distributions in pulsed-dose rate brachytherapy in breast cancer.

Authors:  Patrycja Mantaj; Grzegorz Zwierzchowski
Journal:  Rep Pract Oncol Radiother       Date:  2013-04-12
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.