Literature DB >> 10500480

Improving data acquisition for fast-scan cyclic voltammetry.

D J Michael1, J D Joseph, M R Kilpatrick, E R Travis, R M Wightman.   

Abstract

Described is an improved data acquisition system for fast-scan cyclic voltammetry (FSCV). The system was designed to significantly diminish noise sources that were identified in previously recorded FSCV measurements for the detection of neurotransmitters. Minimized noise is necessary to observe the low concentrations of neurotransmitters that are physiologically important. The system was based on a high-speed, 16-bit AD/DA acquisition board that allowed high scan rates and better resolved the small faradaic currents which remained after background subtraction. Irregularities that occur when independent timing sources are used for generation of the voltage waveform and collection of the current can create large noise artifacts near the voltage limits during FSCV. These were eliminated by the use of a single acquisition board that generated the voltage waveform and collected the current. Noise from frequency drift of the power line was eliminated through the use of a phase-locked loop. To demonstrate the improved performance of the system, data were collected using carbon-fiber microelectrodes in a flow injection analysis system and in brain slices. This new data acquisition system performed significantly better than another system previously used in our laboratory without these features. The improved detection limits of the new system allowed clearly resolved current spikes featuring pre-release "feet" to be recorded adjacent to individual mast cells following chemical stimulation. When combined with false-color plots, the low-noise system facilitated identification of dopamine release in a freely moving animal.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10500480     DOI: 10.1021/ac990491+

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  28 in total

1.  In vivo comparison of norepinephrine and dopamine release in rat brain by simultaneous measurements with fast-scan cyclic voltammetry.

Authors:  Jinwoo Park; Pavel Takmakov; R Mark Wightman
Journal:  J Neurochem       Date:  2011-10-20       Impact factor: 5.372

2.  Development of the Wireless Instantaneous Neurotransmitter Concentration System for intraoperative neurochemical monitoring using fast-scan cyclic voltammetry.

Authors:  Jonathan M Bledsoe; Christopher J Kimble; Daniel P Covey; Charles D Blaha; Filippo Agnesi; Pedram Mohseni; Sidney Whitlock; David M Johnson; April Horne; Kevin E Bennet; Kendall H Lee; Paul A Garris
Journal:  J Neurosurg       Date:  2009-10       Impact factor: 5.115

3.  Characterization of local pH changes in brain using fast-scan cyclic voltammetry with carbon microelectrodes.

Authors:  Pavel Takmakov; Matthew K Zachek; Richard B Keithley; Elizabeth S Bucher; Gregory S McCarty; R Mark Wightman
Journal:  Anal Chem       Date:  2010-11-03       Impact factor: 6.986

Review 4.  Fast-Scan Cyclic Voltammetry: Chemical Sensing in the Brain and Beyond.

Authors:  James G Roberts; Leslie A Sombers
Journal:  Anal Chem       Date:  2017-12-15       Impact factor: 6.986

5.  Rank estimation and the multivariate analysis of in vivo fast-scan cyclic voltammetric data.

Authors:  Richard B Keithley; Regina M Carelli; R Mark Wightman
Journal:  Anal Chem       Date:  2010-07-01       Impact factor: 6.986

6.  Development of the Mayo Investigational Neuromodulation Control System: toward a closed-loop electrochemical feedback system for deep brain stimulation.

Authors:  Su-Youne Chang; Christopher J Kimble; Inyong Kim; Seungleal B Paek; Kenneth R Kressin; Joshua B Boesche; Sidney V Whitlock; Diane R Eaker; Aimen Kasasbeh; April E Horne; Charles D Blaha; Kevin E Bennet; Kendall H Lee
Journal:  J Neurosurg       Date:  2013-10-11       Impact factor: 5.115

7.  Differential quantal release of histamine and 5-hydroxytryptamine from mast cells of vesicular monoamine transporter 2 knockout mice.

Authors:  E R Travis; Y M Wang; D J Michael; M G Caron; R M Wightman
Journal:  Proc Natl Acad Sci U S A       Date:  2000-01-04       Impact factor: 11.205

8.  A voltammetric and mathematical analysis of histaminergic modulation of serotonin in the mouse hypothalamus.

Authors:  Srimal Samaranayake; Aya Abdalla; Rhiannon Robke; H Frederik Nijhout; Michael C Reed; Janet Best; Parastoo Hashemi
Journal:  J Neurochem       Date:  2016-06-27       Impact factor: 5.372

9.  Controlled iontophoresis coupled with fast-scan cyclic voltammetry/electrophysiology in awake, freely moving animals.

Authors:  Anna M Belle; Catarina Owesson-White; Natalie R Herr; Regina M Carelli; R Mark Wightman
Journal:  ACS Chem Neurosci       Date:  2013-03-26       Impact factor: 4.418

10.  Carbon-fiber microelectrodes modified with 4-sulfobenzene have increased sensitivity and selectivity for catecholamines.

Authors:  Andre Hermans; Andrew T Seipel; Charles E Miller; R Mark Wightman
Journal:  Langmuir       Date:  2006-02-28       Impact factor: 3.882

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.