Literature DB >> 10498518

An investigation of the flow dependence of temperature gradients near large vessels during steady state and transient tissue heating.

M C Kolios1, A E Worthington, D W Holdsworth, M D Sherar, J W Hunt.   

Abstract

Temperature distributions measured during thermal therapy are a major prognostic factor of the efficacy and success of the procedure. Thermal models are used to predict the temperature elevation of tissues during heating. Theoretical work has shown that blood flow through large blood vessels plays an important role in determining temperature profiles of heated tissues. In this paper, an experimental investigation of the effects of large vessels on the temperature distribution of heated tissue is performed. The blood flow dependence of steady state and transient temperature profiles created by a cylindrical conductive heat source and an ultrasound transducer were examined using a fixed porcine kidney as a flow model. In the transient experiments, a 20 s pulse of hot water, 30 degrees C above ambient, heated the tissues. Temperatures were measured at selected locations in steps of 0.1 mm. It was observed that vessels could either heat or cool tissues depending on the orientation of the vascular geometry with respect to the heat source and that these effects are a function of flow rate through the vessels. Temperature gradients of 6 degrees C mm(-1) close to large vessels were routinely measured. Furthermore, it was observed that the temperature gradients caused by large vessels depended on whether the heating source was highly localized (i.e. a hot needle) or more distributed (i.e. external ultrasound). The gradients measured near large vessels during localized heating were between two and three times greater than the gradients measured during ultrasound heating at the same location, for comparable flows. Moreover, these gradients were more sensitive to flow variations for the localized needle heating. X-ray computed tomography data of the kidney vasculature were in good spatial agreement with the locations of all of the temperature variations measured. The three dimensional vessel path observed could account for the complex features of the temperature profiles. The flow dependences of the transient temperature profiles near large vessels during the pulsed experiments were consistent with the temperature distributions measured in the steady state experiments and provided unique insights into the process of convective heat transfer in tissues. Finally, it was shown that even for very short treatment times (3-20 s), large vessels had significant effects on the tissue temperature distributions.

Mesh:

Year:  1999        PMID: 10498518     DOI: 10.1088/0031-9155/44/6/304

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Magnetic resonance temperature imaging-based quantification of blood flow-related energy losses.

Authors:  Christopher Dillon; Robert Roemer; Allison Payne
Journal:  NMR Biomed       Date:  2015-05-14       Impact factor: 4.044

2.  Online feedback focusing algorithm for hyperthermia cancer treatment.

Authors:  Kung-Shan Cheng; Vadim Stakhursky; Paul Stauffer; Mark Dewhirst; Shiva K Das
Journal:  Int J Hyperthermia       Date:  2007-11       Impact factor: 3.914

3.  The Flow of Blood-Based Hybrid Nanofluids with Couple Stresses by the Convergent and Divergent Channel for the Applications of Drug Delivery.

Authors:  Anwar Saeed; Niqab Khan; Taza Gul; Wiyada Kumam; Wajdi Alghamdi; Poom Kumam
Journal:  Molecules       Date:  2021-10-20       Impact factor: 4.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.