Literature DB >> 10497933

Preliminary comparison of precursor scans and liquid chromatography-tandem mass spectrometry on a hybrid quadrupole time-of-flight mass spectrometer.

C Borchers1, C E Parker, L J Deterding, K B Tomer.   

Abstract

Recent mass spectrometry instrumentation developments include the appearance of novel hybrid tandem instrumentation, Q-TOF, consisting of a quadrupole mass analyzer (MS1) and a time-of-flight (TOF) analyzer. The TOF analyzer is not scanned, but collects all fragment ions entering the analyzer at a given time. Thus, the typical precursor scan experiment cannot be performed. Instead, a full MS-MS spectrum can be acquired for each mass passed by MS1. Appropriate data manipulation, i.e. extracted ion current chromatograms, can correlate specific fragment ion formation to the parent ion. Precursor scanning and LC-MS-MS are compared on a Q-TOF instrument for the determination of protein modifications, including acetylation and phosphorylation. Model peptides used for phosphopeptide detection were generated from a mixture of beta-casein. Model acetylated peptides were generated from a mixture of acetylated substance P1-9 and substance P1-11. The results were then applied to a more complex mixture, a digest of HIV-p24. Results indicate that precursor scanning is useful for screening, but that LC-MS-MS has a sensitivity advantage and is less susceptible to suppression effects. LC-MS-MS, therefore, appears to be better for the detection of trace components in complex mixtures.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10497933     DOI: 10.1016/s0021-9673(99)00479-3

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  10 in total

1.  Characterization of a discontinuous epitope of the human immunodeficiency virus (HIV) core protein p24 by epitope excision and differential chemical modification followed by mass spectrometric peptide mapping analysis.

Authors:  E O Hochleitner; C Borchers; C Parker; R J Bienstock; K B Tomer
Journal:  Protein Sci       Date:  2000-03       Impact factor: 6.725

2.  Rapidly switchable matrix-assisted laser desorption/ionization and electrospray quadrupole-time-of-flight mass spectrometry for protein identification.

Authors:  A N Krutchinsky; W Zhang; B T Chait
Journal:  J Am Soc Mass Spectrom       Date:  2000-06       Impact factor: 3.109

3.  Determination of the relative energies of activation for the dissociation of aromatic versus aliphatic phosphopeptides by ESI-FTICR-MS and IRMPD.

Authors:  Jason W Flora; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2004-01       Impact factor: 3.109

Review 4.  Mass spectrometry-based strategies for characterization of histones and their post-translational modifications.

Authors:  Xiaodan Su; Chen Ren; Michael A Freitas
Journal:  Expert Rev Proteomics       Date:  2007-04       Impact factor: 3.940

5.  A novel high-capacity ion trap-quadrupole tandem mass spectrometer.

Authors:  Andrew N Krutchinsky; Herbert Cohen; Brian T Chait
Journal:  Int J Mass Spectrom       Date:  2007       Impact factor: 1.986

6.  Effect of cysteic acid position on the negative ion fragmentation of proteolytic derived peptides.

Authors:  Brad J Williams; Kevin L Kmiec; William K Russell; David H Russell
Journal:  J Am Soc Mass Spectrom       Date:  2011-01-20       Impact factor: 3.109

7.  Identification of protein-derived tyrosyl radical in the reaction of cytochrome c and hydrogen peroxide: characterization by ESR spin-trapping, HPLC and MS.

Authors:  Steven Yue Qian; Yeong-Renn Chen; Leesa J Deterding; Yang C Fann; Colin F Chignell; Kenneth B Tomer; Ronald P Mason
Journal:  Biochem J       Date:  2002-04-15       Impact factor: 3.857

8.  Single Analyzer Precursor Ion Scans in a Linear Quadrupole Ion Trap Using Orthogonal Double Resonance Excitation.

Authors:  Dalton T Snyder; R Graham Cooks
Journal:  J Am Soc Mass Spectrom       Date:  2017-06-02       Impact factor: 3.109

9.  The application of a hypothesis-driven strategy to the sensitive detection and location of acetylated lysine residues.

Authors:  John R Griffiths; Richard D Unwin; Caroline A Evans; Siân H Leech; Bernard M Corfe; Anthony D Whetton
Journal:  J Am Soc Mass Spectrom       Date:  2007-05-06       Impact factor: 3.109

10.  Lysine Acetylation Reshapes the Downstream Signaling Landscape of Vav1 in Lymphocytes.

Authors:  Sonia Rodríguez-Fdez; Lucía Fernández-Nevado; L Francisco Lorenzo-Martín; Xosé R Bustelo
Journal:  Cells       Date:  2020-03-04       Impact factor: 6.600

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.