Literature DB >> 10493374

Balloon-assisted Guglielmi detachable coiling of wide-necked aneurysms: Part I--experimental evaluation.

Y Akiba1, Y Murayama, F Viñuela, M A Lefkowitz, G R Duckwiler, Y P Gobin.   

Abstract

OBJECTIVE: Balloon-assisted technique is a promising technical adjunct to use of Guglielmi detachable coils for embolization of wide-necked aneurysms. In this study using experimental aneurysms in swine, the safety and long-term efficacy of this technique were evaluated.
METHODS: Sixteen wide-necked aneurysms (sidewall model) were surgically created in common carotid arteries of swine. In the acute study of eight aneurysms, intra-aneurysmal pressure changes were recorded during balloon inflation in different positions of the balloon relative to the neck of the aneurysm. In the chronic study, eight aneurysms were treated with this technique, and follow-up angiography was performed 14 days postembolization. The animals were then killed for macroscopic evaluation.
RESULTS: In the acute study, the systolic intra-aneurysmal blood pressure increased with balloon inflation at the distal portion of the neck and with balloon inflation/occlusion across the entire neck of the aneurysm. In the chronic study, seven of eight cases were embolized with satisfactory occlusion, and six showed no coil displacement on the follow-up angiogram. In five cases, macroscopic evaluation of the aneurysm showed that the coils were compacted at the neck of the aneurysm with a concave shape consistent with the shape of the inflated balloon across its neck.
CONCLUSION: This preliminary study indicates that balloon-assisted Guglielmi detachable coiling technology may produce a temporary increase of pressure within the aneurysm while occluding the aneurysmal neck during coil delivery. This sudden change of intra-aneurysmal pressure may potentially be the cause-of aneurysm rupture in the clinical setting. The balloon must be inflated and deflated very slowly to minimize these potentially risky hemodynamic changes. Although angiographic follow-up showed successful obliteration of aneurysms, further long-term angiographic studies are necessary to establish the durability of this technique.

Entities:  

Mesh:

Year:  1999        PMID: 10493374     DOI: 10.1097/00006123-199909000-00022

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  12 in total

1.  Stent-assisted coil embolization of intracranial aneurysms using the Solitaire™ AB Neurovascular Remodeling Device: initial and midterm follow-up results.

Authors:  Christin Clajus; Vojtech Sychra; Christoph Strasilla; Joachim Klisch
Journal:  Neuroradiology       Date:  2013-02-06       Impact factor: 2.804

2.  Cyanoacrylate embolization of experimental aneurysms.

Authors:  Jean Raymond; France Berthelet; Anne-Cécile Desfaits; Igor Salazkin; Daniel Roy
Journal:  AJNR Am J Neuroradiol       Date:  2002-01       Impact factor: 3.825

3.  An experimental aneurysm model: a training model for neurointerventionalists.

Authors:  I Q Grunwald; B Romeike; R Eymann; C Roth; T Struffert; W Reith
Journal:  Interv Neuroradiol       Date:  2006-06-15       Impact factor: 1.610

4.  Intraprocedural aneurysmal rupture during coil embolization of brain aneurysms: role of balloon-assisted coiling.

Authors:  A Santillan; Y P Gobin; E D Greenberg; L Z Leng; H A Riina; P E Stieg; A Patsalides
Journal:  AJNR Am J Neuroradiol       Date:  2012-05-03       Impact factor: 3.825

5.  Anatomic results and complications of stent-assisted coil embolization of intracranial aneurysms.

Authors:  S R Kim; N Vora; T G Jovin; R Gupta; A Thomas; A Kassam; K Lee; Y Gologorsky; B Jankowitz; N Panapitiya; A Aleu; E Sandhu; E Crago; A Hricik; M Gallek; M B Horowitz
Journal:  Interv Neuroradiol       Date:  2008-10-08       Impact factor: 1.610

6.  Endovascular treatment of experimental aneurysms by use of a combination of liquid embolic agents and protective devices.

Authors:  Y Murayama; F Viñuela; S Tateshima; F Viñuela; Y Akiba
Journal:  AJNR Am J Neuroradiol       Date:  2000-10       Impact factor: 3.825

7.  Analysis of clinical and radiological outcomes in microsurgical and endovascular treatment of basilar apex aneurysms.

Authors:  Sung-Chul Jin; Jae Sung Ahn; Byung-Duk Kwun; Do-Hoon Kwon
Journal:  J Korean Neurosurg Soc       Date:  2009-04-30

8.  CT and MR imaging findings and their implications in the follow-up of patients with intracranial aneurysms treated with endosaccular occlusion with onyx.

Authors:  Isil Saatci; H Saruhan Cekirge; Elisa F M Ciceri; Michel E Mawad; A Gulsun Pamuk; Aytekin Besim
Journal:  AJNR Am J Neuroradiol       Date:  2003-04       Impact factor: 3.825

9.  Complications of Neuroform stent in endovascular treatment of intracranial aneurysms.

Authors:  Abutaher M Yahia; Vickie Gordon; John Whapham; Ali Malek; J Steel; Richard D Fessler
Journal:  Neurocrit Care       Date:  2008       Impact factor: 3.210

10.  Long-term results with Matrix coils vs. GDC: an angiographic and histopathological comparison.

Authors:  C Roth; T Struffert; I Q Grunwald; B F M Romeike; C Krick; P Papanagiotou; P Krampe; W Reith
Journal:  Neuroradiology       Date:  2008-05-29       Impact factor: 2.804

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.