Socket/stump interface dynamic pressure distributions recorded during the prosthetic stance phase of gait of a trans-tibial amputee wearing a hydrocast socket.

P Convery1, A W Buis.   

Abstract

Force sensing resistors (FSR) have been used to measure dynamic stump/socket interface pressures during the gait of a trans-tibial amputee. A total of 350 pressure sensors were attached to the inner wall of a hydrocast socket. Data were sampled at 150 Hz during approximately 0.8 seconds of prosthetic stance of gait. The dynamic pressure distributions within a hand cast socket reported by Convery and Buis (1998) are compared with those monitored within a hydrocast socket for the same amputee. The pressure gradients within the hydrocast socket are less than that of the hand cast Patellar-Tendon-Bearing (PTB) socket. The proximal "ring" of high pressure in the hand cast PTB socket is replaced with a more distal pressure in the hydrocast socket.

Mesh:

Year:  1999        PMID: 10493137     DOI: 10.3109/03093649909071621

Source DB:  PubMed          Journal:  Prosthet Orthot Int        ISSN: 0309-3646            Impact factor:   1.895


  6 in total

1.  Evaluation of Force Sensing Resistors for the Measurement of Interface Pressures in Lower Limb Prosthetics.

Authors:  Eric Swanson; Ethan Weathersby; John Cagle; Joan E Sanders
Journal:  J Biomech Eng       Date:  2019-04-24       Impact factor: 2.097

2.  Clinical implication of interface pressure for a new prosthetic suspension system.

Authors:  Hossein Gholizadeh; Noor Azuan Abu Osman; Arezoo Eshraghi; Nasrul Anuar Abd Razak
Journal:  Biomed Eng Online       Date:  2014-06-30       Impact factor: 2.819

3.  Interface Pressure System to Compare the Functional Performance of Prosthetic Sockets during the Gait in People with Trans-Tibial Amputation.

Authors:  Salvador Ibarra Aguila; Gisel J Sánchez; Eric E Sauvain; B Alemon; Rita Q Fuentes-Aguilar; Joel C Huegel
Journal:  Sensors (Basel)       Date:  2020-12-09       Impact factor: 3.576

4.  The effect of different skin-ankle brace application pressures on quiet single-limb balance and electromyographic activation onset of lower limb muscles.

Authors:  Emmanuel S Papadopoulos; Christos Nikolopoulos; Athanasios Badekas; George Vagenas; Stamatios A Papadakis; Spyros Athanasopoulos
Journal:  BMC Musculoskelet Disord       Date:  2007-09-12       Impact factor: 2.362

5.  The capability of fiber Bragg grating sensors to measure amputees' trans-tibial stump/socket interface pressures.

Authors:  Ebrahim A Al-Fakih; Noor Azuan Abu Osman; Arezoo Eshraghi; Faisal Rafiq Mahamd Adikan
Journal:  Sensors (Basel)       Date:  2013-08-12       Impact factor: 3.576

Review 6.  Techniques for Interface Stress Measurements within Prosthetic Sockets of Transtibial Amputees: A Review of the Past 50 Years of Research.

Authors:  Ebrahim A Al-Fakih; Noor Azuan Abu Osman; Faisal Rafiq Mahmad Adikan
Journal:  Sensors (Basel)       Date:  2016-07-20       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.