Accuracy of the i-STAT bedside blood gas analyser.

S Sediame1, F Zerah-Lancner, M P d'Ortho, S Adnot, A Harf.   

Abstract

The performance of the i-STAT portable clinical analyser for measuring blood gases and pH was evaluated with reference to a conventional blood gas analyser (ABL520 Radiometer). Ninety-two samples from the routine blood gas analysis laboratory were chosen according to a wide distribution of partial pressure of carbon dioxide (Pa,CO2), partial pressure oxygen (Pa,O2) and pH and then analysed. All measurements were performed in duplicate by trained technicians from the central hospital laboratory. Differences between duplicate measurements were computed for Pa,CO2: (1.2 versus 0.4%), Pa,O2 (1.7 versus 1.1%) and pH (0.06 versus 0.02%), for the i-STAT and ABL520, respectively. pH and Pa,CO2 values measured with the i-STAT were very close to those obtained with the ABL520, the difference (mean+/-SD) being 0.006+/-0.018 and -0.13+/-0.17 kPa, respectively. Statistical analysis showed that the differences between analysers did not depend on values of pH or Pa,CO2. The performance of the analysers depended on the level of PO2. Below 15 kPa (n=48), the two systems gave nearly identical values, the mean difference was 0.01+/-0.37 kPa. Between 16 and 55 kPa (n=44), there was a systematic but small (-0.69+/-0.67 kPa) underestimation of Pa,O2 measured with the i-STAT (p<10(-8)). In conclusion, this study shows that blood gas analysis using the i-STAT portable device is comparable with that performed by a conventional laboratory blood gas analyser.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10489854     DOI: 10.1034/j.1399-3003.1999.14a36.x

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  8 in total

1.  Evaluation of the i-STAT point-of-care analyzer in critically ill adult patients.

Authors:  Jacoline Steinfelder-Visscher; Steven Teerenstra; Jacqueline M T Klein Gunnewiek; Patrick W Weerwind
Journal:  J Extra Corpor Technol       Date:  2008-03

2.  The influence of physiotherapy and suction on respiratory deadspace in ventilated children.

Authors:  Eleanor Main; Janet Stocks
Journal:  Intensive Care Med       Date:  2004-05-08       Impact factor: 17.440

3.  Respiratory physiotherapy vs. suction: the effects on respiratory function in ventilated infants and children.

Authors:  Eleanor Main; Rosemary Castle; Di Newham; Janet Stocks
Journal:  Intensive Care Med       Date:  2004-05-06       Impact factor: 17.440

4.  Quantum Blue Reduces the Severity of Woody Breast Myopathy via Modulation of Oxygen Homeostasis-Related Genes in Broiler Chickens.

Authors:  Elizabeth Greene; Joshua Flees; Sina Dadgar; Barbara Mallmann; Sara Orlowski; Ahmed Dhamad; Samuel Rochell; Michael Kidd; Caroline Laurendon; Hayley Whitfield; Charles Brearley; Narasimhan Rajaram; Carrie Walk; Sami Dridi
Journal:  Front Physiol       Date:  2019-10-01       Impact factor: 4.566

5.  Developing an animal model to detect drug-drug interactions impacting drug-induced respiratory depression.

Authors:  Lin Xu; Ashok Chockalingam; Sharron Stewart; Katherine Shea; Murali K Matta; Suresh Narayanasamy; Nageswara R Pilli; Donna A Volpe; James Weaver; Hao Zhu; Michael C Davis; Rodney Rouse
Journal:  Toxicol Rep       Date:  2020-01-25

6.  Ketone Bodies Impact on Hypoxic CO2 Retention Protocol During Exercise.

Authors:  Philip J Prins; Jeffrey D Buxton; Tyler S McClure; Dominic P D'Agostino; Dana L Ault; Gary L Welton; Dalton W Jones; Adam D Atwell; Macey A Slack; Marah L Slack; Chloe E Williams; Morgan E Blanchflower; Kristia K Kannel; Madison N Faulkner; Hannah L Szmaciasz; Stephanie M Croll; Lindsey M Stanforth; Tim D Harris; Holton C Gwaltney; Andrew P Koutnik
Journal:  Front Physiol       Date:  2021-12-13       Impact factor: 4.566

7.  Oximetry neither to prescribe long-term oxygen therapy nor to screen for severe hypoxaemia.

Authors:  Yves Lacasse; Sébastien Thériault; Benoît St-Pierre; Sarah Bernard; Frédéric Sériès; Harold Jean Bernatchez; François Maltais
Journal:  ERJ Open Res       Date:  2021-10-18

8.  Plasma ATP concentration and venous oxygen content in the forearm during dynamic handgrip exercise.

Authors:  Rachel E Wood; Connie Wishart; Philip J Walker; Christopher D Askew; Ian B Stewart
Journal:  BMC Physiol       Date:  2009-12-15
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.