OBJECTIVE: To determine the value of routine patch angioplasty and intraoperative duplex ultrasonography (US) during carotid endarterectomy (CEA) for high-grade internal carotid artery stenosis. PATIENTS AND METHODS: The charts of 102 consecutive patients who underwent CEA with routine patching and intraoperative duplex US for treatment of high-grade carotid stenosis between June 1991 and January 1997 were reviewed retrospectively. Recurrent stenosis was defined as a narrowing in the common or internal carotid artery of more than 40%. RESULTS: Of 102 patients, 65 (63.7%) were men, and 37 (36.3%) were women (mean age, 72.4 years). Thirteen patients (12.7%) had bilateral CEAs. Intraoperative duplex US revealed abnormalities during 29 (25.2%) of 115 CEAs; 14 abnormalities (12.2%) were major and underwent immediate revision. No perioperative neurologic events or deaths occurred. Mean length of follow-up was 21.3 months (range, 1.3-72.6 months). Late neurologic events occurred in 2 patients, and 5 patients died during follow-up. All neurologic events and deaths were unrelated to the patients' carotid surgery. Twelve patients (11.8%) developed moderate restenosis (40%-69%). In 4 of these patients restenosis resolved during further follow-up. No patient developed severe recurrent carotid stenosis. CONCLUSION: Morbidity and mortality following CEA with routine patch angioplasty and intraoperative duplex US appear to be low. Routine intraoperative duplex US detects correctable technical problems that subsequently lead to a low incidence of symptomatic stenosis. The low incidence of recurrent stenosis suggests that routine postoperative follow-up may not be necessary or cost-effective unless the patient has symptoms or a contralateral stenosis.
OBJECTIVE: To determine the value of routine patch angioplasty and intraoperative duplex ultrasonography (US) during carotid endarterectomy (CEA) for high-grade internal carotid artery stenosis. PATIENTS AND METHODS: The charts of 102 consecutive patients who underwent CEA with routine patching and intraoperative duplex US for treatment of high-grade carotid stenosis between June 1991 and January 1997 were reviewed retrospectively. Recurrent stenosis was defined as a narrowing in the common or internal carotid artery of more than 40%. RESULTS: Of 102 patients, 65 (63.7%) were men, and 37 (36.3%) were women (mean age, 72.4 years). Thirteen patients (12.7%) had bilateral CEAs. Intraoperative duplex US revealed abnormalities during 29 (25.2%) of 115 CEAs; 14 abnormalities (12.2%) were major and underwent immediate revision. No perioperative neurologic events or deaths occurred. Mean length of follow-up was 21.3 months (range, 1.3-72.6 months). Late neurologic events occurred in 2 patients, and 5 patients died during follow-up. All neurologic events and deaths were unrelated to the patients' carotid surgery. Twelve patients (11.8%) developed moderate restenosis (40%-69%). In 4 of these patientsrestenosis resolved during further follow-up. No patient developed severe recurrent carotid stenosis. CONCLUSION: Morbidity and mortality following CEA with routine patch angioplasty and intraoperative duplex US appear to be low. Routine intraoperative duplex US detects correctable technical problems that subsequently lead to a low incidence of symptomatic stenosis. The low incidence of recurrent stenosis suggests that routine postoperative follow-up may not be necessary or cost-effective unless the patient has symptoms or a contralateral stenosis.
Authors: Jessica B Wallaert; Philip P Goodney; John J Vignati; David H Stone; Brian W Nolan; Daniel J Bertges; Daniel B Walsh; Jack L Cronenwett Journal: J Vasc Surg Date: 2011-03-31 Impact factor: 4.268
Authors: Christoph Knappich; Thomas Lang; Pavlos Tsantilas; Sofie Schmid; Michael Kallmayer; Bernhard Haller; Hans-Henning Eckstein Journal: Ann Transl Med Date: 2021-07