Literature DB >> 10482107

Optical cross-sectional assessment of the macula by retinal thickness analyzer in optic disk pit maculopathy.

Y Oshima1, K Emi.   

Abstract

PURPOSE: To assess the morphologic changes in optic disk pit maculopathy.
METHOD: Case report. A 45-year-old woman with optic disk pit maculopathy in the left eye was examined with the scanning retinal thickness analyzer before and after vitrectomy with intravitreal gas tamponade.
RESULTS: Preoperatively, optical cross-sectional retinal thickness analyzer images clearly demonstrated the extent of retinoschisis and outer layer detachment in the macula. Postoperatively, the retinal thickness analyzer images showed that retinal thickening decreased as the intraretinal fluid in the schisis cavity was absorbed and then gradually decreased further as the outer layer detachment in the fovea resolved.
CONCLUSIONS: Scanning retinal thickness analyzer can be used to diagnose and monitor the structural changes of the macula lesion in optic disk pit maculopathy. Vitrectomy with gas tamponade may be effective for treating this disease.

Entities:  

Mesh:

Year:  1999        PMID: 10482107     DOI: 10.1016/s0002-9394(99)00054-9

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  2 in total

1.  Eccentricity and measurement variability and repeatability with the retinal thickness analyser.

Authors:  E D Gilmore; C Hudson
Journal:  Br J Ophthalmol       Date:  2004-01       Impact factor: 4.638

2.  Optical coherence tomography in optic pit maculopathy managed with vitrectomy-laser-gas.

Authors:  José García-Arumí; Borja Corcóstegui Guraya; Ana Boixadera Espax; Vicente Martínez Castillo; Laura Sararols Ramsay; R Max Motta
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2004-04-07       Impact factor: 3.117

  2 in total