Frequency dependence of EPR signal-to-noise.

G A Rinard1, R W Quine, J R Harbridge, R Song, G R Eaton, S S Eaton.   

Abstract

Direct measurements of electron spin-echo signal and noise in well-characterized X-band and S-band spectrometers agree with predictions of frequency dependence based on first principles. For the particular spectrometers compared, the echo at 9.52 GHz was 9.5 times larger than the echo at 2.68 GHz, after scaling for differences in spectrometer gain. The calculated ratio was 7.6. This result contrasts with prior predictions that the frequency dependence would be much greater. Copyright 1999 Academic Press.

Mesh:

Year:  1999        PMID: 10479565     DOI: 10.1006/jmre.1999.1798

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  9 in total

1.  Comparison of electron paramagnetic resonance methods to determine distances between spin labels on human carbonic anhydrase II.

Authors:  M Persson; J R Harbridge; P Hammarström; R Mitri; L G Mårtensson; U Carlsson; G R Eaton; S S Eaton
Journal:  Biophys J       Date:  2001-06       Impact factor: 4.033

2.  A signal-to-noise standard for pulsed EPR.

Authors:  Gareth R Eaton; Sandra S Eaton; Richard W Quine; Deborah Mitchell; Velavan Kathirvelu; Ralph T Weber
Journal:  J Magn Reson       Date:  2010-04-24       Impact factor: 2.229

3.  Magnetic Resonance Spectra and Statistical Geometry.

Authors:  Keith A Earle; Laxman Mainali; Indra Dev Sahu; David J Schneider
Journal:  Appl Magn Reson       Date:  2010-01-01       Impact factor: 0.831

4.  Electron spin relaxation of copper(II) complexes in glassy solution between 10 and 120 K.

Authors:  Alistair J Fielding; Stephen Fox; Glenn L Millhauser; Madhuri Chattopadhyay; Peter M H Kroneck; Günter Fritz; Gareth R Eaton; Sandra S Eaton
Journal:  J Magn Reson       Date:  2005-12-15       Impact factor: 2.229

5.  Quantitative rapid scan EPR spectroscopy at 258 MHz.

Authors:  Richard W Quine; George A Rinard; Sandra S Eaton; Gareth R Eaton
Journal:  J Magn Reson       Date:  2010-03-21       Impact factor: 2.229

6.  A Pulse EPR 25 mT magnetometer with 10ppm resolution.

Authors:  Subramanian V Sundramoorthy; Boris Epel; Howard J Halpern
Journal:  Appl Magn Reson       Date:  2017-06-05       Impact factor: 0.831

7.  Frequency Dependence of Pulsed EPR Experiments.

Authors:  Sandra S Eaton; Gareth R Eaton
Journal:  Concepts Magn Reson Part A Bridg Educ Res       Date:  2009-11-01       Impact factor: 0.481

8.  Development of an L-band resonator optimized for fast scan EPR imaging of the mouse head.

Authors:  Alexandre Samouilov; Denis Komarov; Sergey Petryakov; Arkadiy Iosilevich; Jay L Zweier
Journal:  Magn Reson Med       Date:  2021-05-03       Impact factor: 3.737

Review 9.  EPR Everywhere.

Authors:  Joshua R Biller; Joseph E McPeak
Journal:  Appl Magn Reson       Date:  2021-01-24       Impact factor: 0.831

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.