Evaluation of a testing method for the fatigue performance of total knee tibial trays.

S P Ahir1, G W Blunn, H Haider, P S Walker.   

Abstract

Catastrophic failure of tibial baseplates due to fatigue fracture have occurred in patients. The International Standards Organisation (ISO) have proposed an endurance test to ensure a safety level for trays with respect to this problem. At present the magnitude of the applied load has not been defined. The purpose of this study is to evaluate the ISO test by comparing the results of two tibial trays: one with a clinical history of fracture of the tibial baseplate in some cases (Kinematic) and one without such a record (Kinemax). A load of 2000 N was selected, representing the peak force during the normal walking cycle. Finite element analysis (FEA) predicted that both the Kinematic and Kinemax trays would rapidly fail for two defined contact positions. Mechanical testing performed on both these components confirmed the FEA predictions. However, under service conditions, the Kinematic tray has been reported to have a failure of only 1-2%, the failure occurring at a mean of 54 months for early fracture and 7 years for late fracture. There are no published reports of failed Kinemax trays. It is concluded that the ISO test is an exaggeration of reality when a physiological load is used. As a result of our study we propose that a load of 500 N would effectively screen components with respect to the ISO test conditions for the likelihood of fracture.

Entities:  

Mesh:

Year:  1999        PMID: 10476843     DOI: 10.1016/s0021-9290(99)00094-9

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  3 in total

1.  Tribological and mechanical performance evaluation of metal prosthesis components manufactured via metal injection molding.

Authors:  Virginia Melli; Mateusz Juszczyk; Enrico Sandrini; Giovanni Bolelli; Benedetta Bonferroni; Luca Lusvarghi; Alberto Cigada; Tiziano Manfredini; Luigi De Nardo
Journal:  J Mater Sci Mater Med       Date:  2015-01-11       Impact factor: 3.896

2.  The effect of malrotation of tibial component of total knee arthroplasty on tibial insert during high flexion using a finite element analysis.

Authors:  Kei Osano; Ryuji Nagamine; Mitsugu Todo; Makoto Kawasaki
Journal:  ScientificWorldJournal       Date:  2014-05-08

3.  Finite element analysis of the tibial bone graft in cementless total knee arthroplasty.

Authors:  Koji Totoribe; Etsuo Chosa; Go Yamako; Hiroaki Hamada; Koki Ouchi; Shutaro Yamashita; Gang Deng
Journal:  J Orthop Surg Res       Date:  2018-05-16       Impact factor: 2.359

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.