Literature DB >> 10476839

Femoral strength is better predicted by finite element models than QCT and DXA.

D D Cody1, G J Gross, F J Hou, H J Spencer, S A Goldstein, D P Fyhrie.   

Abstract

Clinicians and patients would benefit if accurate methods of predicting and monitoring bone strength in-vivo were available. A group of 51 human femurs (age range 21-93; 23 females, 28 males) were evaluated for bone density and geometry using quantitative computed tomography (QCT) and dual energy X-ray absorptiometry (DXA). Regional bone density and dimensions obtained from QCT and DXA were used to develop statistical models to predict femoral strength ex vivo. The QCT data also formed the basis of a three-dimensional finite element (FE) models to predict structural stiffness. The femurs were separated into two groups; a model training set (n = 25) was used to develop statistical models to predict ultimate load, and a test set (n = 26) was used to validate these models. The main goal of this study was to test the ability of DXA, QCT and FE techniques to predict fracture load non-invasively, in a simple load configuration which produces predominantly femoral neck fractures. The load configuration simulated the single stance phase portion of normal gait; in 87% of the specimens, clinical appearing sub-capital fractures were produced. The training/test study design provided a tool to validate that the predictive models were reliable when used on specimens with "unknown" strength characteristics. The FE method explained at least 20% more of the variance in strength than the DXA models. Planned refinements of the FE technique are expected to further improve these results. Three-dimensional FE models are a promising method for predicting fracture load, and may be useful in monitoring strength changes in vivo.

Entities:  

Mesh:

Year:  1999        PMID: 10476839     DOI: 10.1016/s0021-9290(99)00099-8

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  91 in total

1.  Voxel classification and graph cuts for automated segmentation of pathological periprosthetic hip anatomy.

Authors:  Daniel F Malan; Charl P Botha; Edward R Valstar
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-01-21       Impact factor: 2.924

2.  Number crunching: how and when will numerical models be used in the clinical setting?

Authors:  W Brent Edwards; Karen L Troy
Journal:  Curr Osteoporos Rep       Date:  2011-03       Impact factor: 5.096

Review 3.  Computed tomography-based finite element analysis to assess fracture risk and osteoporosis treatment.

Authors:  Kazuhiro Imai
Journal:  World J Exp Med       Date:  2015-08-20

Review 4.  Bone Imaging and Fracture Risk after Spinal Cord Injury.

Authors:  W Brent Edwards; Thomas J Schnitzer
Journal:  Curr Osteoporos Rep       Date:  2015-10       Impact factor: 5.096

5.  In situ parameter identification of optimal density-elastic modulus relationships in subject-specific finite element models of the proximal femur.

Authors:  Alexander Cong; Jorn Op Den Buijs; Dan Dragomir-Daescu
Journal:  Med Eng Phys       Date:  2010-10-27       Impact factor: 2.242

6.  Three-dimensional X-ray absorptiometry (3D-XA): a method for reconstruction of human bones using a dual X-ray absorptiometry device.

Authors:  S Kolta; A Le Bras; D Mitton; V Bousson; J A de Guise; J Fechtenbaum; J D Laredo; C Roux; W Skalli
Journal:  Osteoporos Int       Date:  2004-12-14       Impact factor: 4.507

7.  Automated registration of hip and spine for longitudinal QCT studies: integration with 3D densitometric and structural analysis.

Authors:  Wenjun Li; Miki Sode; Isra Saeed; Thomas Lang
Journal:  Bone       Date:  2005-09-30       Impact factor: 4.398

8.  Side-artifact errors in yield strength and elastic modulus for human trabecular bone and their dependence on bone volume fraction and anatomic site.

Authors:  Grant Bevill; Sarah K Easley; Tony M Keaveny
Journal:  J Biomech       Date:  2007-07-19       Impact factor: 2.712

9.  Effects of densitometry, material mapping and load estimation uncertainties on the accuracy of patient-specific finite-element models of the scapula.

Authors:  Gianni Campoli; Bart Bolsterlee; Frans van der Helm; Harrie Weinans; Amir A Zadpoor
Journal:  J R Soc Interface       Date:  2014-02-12       Impact factor: 4.118

Review 10.  Bone quality: the determinants of bone strength and fragility.

Authors:  Hélder Fonseca; Daniel Moreira-Gonçalves; Hans-Joachim Appell Coriolano; José Alberto Duarte
Journal:  Sports Med       Date:  2014-01       Impact factor: 11.136

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.