Literature DB >> 10476820

Acuity recovery and cone pigment regeneration after a bleach in patients with retinitis pigmentosa and rhodopsin mutations.

M A Sandberg1, B S Pawlyk, E L Berson.   

Abstract

PURPOSE: To assess visual acuity recovery times and cone photopigment regeneration kinetics after a bleach in the fovea of patients with dominant retinitis pigmentosa due to rhodopsin mutations.
METHODS: The authors measured acuity recovery times by computerized photostress testing in 13 patients with dominant retinitis pigmentosa and one of eight rhodopsin mutations. The authors also measured their time constants of cone photopigment regeneration with a video imaging fundus reflectometer to determine whether acuity recovery time depended on pigment regeneration kinetics. These values were compared with those of normal subjects, by the Mann-Whitney U test. The relationship between acuity recovery time and the time constant of cone photopigment regeneration among the patients was quantified by the Spearman rank correlation.
RESULTS: The visual acuity recovery times, which averaged 22.0 seconds for the patients with retinitis pigmentosa and 11.2 seconds for the normal subjects, were significantly slower for the patient group (P < 0.001). The time constants of cone pigment regeneration, which averaged 172 seconds for the patients with retinitis pigmentosa and 118 seconds for the normal subjects, also were significantly slower for the patient group (P = 0.043). The authors also found a significant, positive correlation between the visual acuity recovery time and the time constant of pigment regeneration for the patients with retinitis pigmentosa (r = 0.65, P = 0.017).
CONCLUSIONS: A slowing of foveal visual acuity recovery and cone pigment regeneration, which are related to each other, can occur in patients with retinitis pigmentosa, due to a rod-specific gene defect.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10476820

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  5 in total

1.  Measurement of cone dark adaptation: a comparison of four psychophysical methods.

Authors:  Allannah J Gaffney; Alison M Binns; Tom H Margrain
Journal:  Doc Ophthalmol       Date:  2013-11-22       Impact factor: 2.379

2.  The repeatability of the Goldmann-Weekers adaptometer for measuring cone adaptation.

Authors:  Allannah J Gaffney; Alison M Binns; Tom H Margrain
Journal:  Doc Ophthalmol       Date:  2011-01-29       Impact factor: 2.379

3.  Design of a novel smartphone-based photostress recovery time test for detecting abnormalities in the macula. A cross-sectional study.

Authors:  Vasileios Karampatakis; Diamantis Almaliotis; Eleni P Papadopoulou; Stavroula Almpanidou
Journal:  Ann Med Surg (Lond)       Date:  2022-04-29

Review 4.  Finding and interpreting genetic variations that are important to ophthalmologists.

Authors:  Edwin M Stone
Journal:  Trans Am Ophthalmol Soc       Date:  2003

5.  Slow Cone Reflectance Changes during Bleaching Determined by Adaptive Optics Scanning Laser Ophthalmoscope in Living Human Eyes.

Authors:  Masakazu Hirota; Suguru Miyagawa; Hiroyuki Kanda; Takao Endo; Tibor Karl Lohmann; Tomomitsu Miyoshi; Takeshi Morimoto; Takashi Fujikado
Journal:  PLoS One       Date:  2015-06-29       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.