Literature DB >> 10475555

Changes in knee alignment after total knee arthroplasty.

S Matsuda1, H Miura, R Nagamine, K Urabe, K Harimaya, T Matsunobu, Y Iwamoto.   

Abstract

Changes in limb alignment after total knee arthroplasty were evaluated in 20 knees replaced with the Miller Galante knee system. The mean follow-up period was 87.4 months. Seventeen of the 20 knees were in the varus position on the initial postoperative radiographs, but the alignment significantly changed to become even more aligned toward varus during the follow-up period. The thickness of the ultra-high-molecular-weight polyethylene (UHMWPE) also decreased significantly in the medial femorotibial joint. The wear of the UHMWPE possibly changed the alignment, and the postoperative alignment had a positive correlation with the wear rate. The components should be implanted so that the mechanical axis intersects the center of the components to prevent worsening of alignment as well as to minimize any such wear.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10475555     DOI: 10.1016/s0883-5403(99)90078-5

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  14 in total

1.  The Influence of Component Alignment and Ligament Properties on Tibiofemoral Contact Forces in Total Knee Replacement.

Authors:  Colin R Smith; Michael F Vignos; Rachel L Lenhart; Jarred Kaiser; Darryl G Thelen
Journal:  J Biomech Eng       Date:  2016-02       Impact factor: 2.097

2.  Varus tibial alignment is associated with greater tibial baseplate migration at 10 years following total knee arthroplasty.

Authors:  Matthew G Teeter; Douglas D Naudie; Richard W McCalden; Xunhua Yuan; David W Holdsworth; Steven J MacDonald; Brent A Lanting
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-11-16       Impact factor: 4.342

3.  Improved design decreases wear in total knee arthroplasty with varus malalignment.

Authors:  Kazutaka Nishikawa; Ken Okazaki; Shuichi Matsuda; Yasutaka Tashiro; Shinya Kawahara; Hiroyuki Nakahara; Shigetoshi Okamoto; Takeshi Shimoto; Hidehiko Higaki; Yukihide Iwamoto
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-16       Impact factor: 4.342

4.  No influence of coronal laxity and alignment on lift-off after well-balanced and aligned total knee arthroplasty.

Authors:  Satoshi Hamai; Hiromasa Miura; Ken Okazaki; Takeshi Shimoto; Hidehiko Higaki; Yukihide Iwamoto
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-17       Impact factor: 4.342

5.  Femoral Component Varus Malposition is Associated with Tibial Aseptic Loosening After TKA.

Authors:  Bum-Sik Lee; Hyun-Ik Cho; Seong-Il Bin; Jong-Min Kim; Byeong-Kyu Jo
Journal:  Clin Orthop Relat Res       Date:  2018-02       Impact factor: 4.176

Review 6.  Osteolysis around total knee arthroplasty: a review of pathogenetic mechanisms.

Authors:  J Gallo; S B Goodman; Y T Konttinen; M A Wimmer; M Holinka
Journal:  Acta Biomater       Date:  2013-05-10       Impact factor: 8.947

7.  A morphometric study of normal and varus knees.

Authors:  Pramod Kumar Puthumanapully; Simon J Harris; Anthony Leong; Justin P Cobb; Andrew A Amis; Jonathan Jeffers
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-09-27       Impact factor: 4.342

8.  Computed tomographic evaluation of femoral component rotation in total knee arthroplasty.

Authors:  Shrinand V Vaidya; Rajesh M Gadhiya; Vaibhav Bagaria; Amar S Ranawat; Chitranjan S Ranawat
Journal:  Indian J Orthop       Date:  2013-01       Impact factor: 1.251

9.  Collateral soft tissue release in primary total knee replacement.

Authors:  Stuart Goudie; Kamal Deep
Journal:  Comput Aided Surg       Date:  2014-04-10

10.  How accurate is anatomic limb alignment in predicting mechanical limb alignment after total knee arthroplasty?

Authors:  Seung Ah Lee; Sang-Hee Choi; Moon Jong Chang
Journal:  BMC Musculoskelet Disord       Date:  2015-10-27       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.