Literature DB >> 10474974

Set-up error & organ motion uncertainty: a review.

J T Booth1, S F Zavgorodni.   

Abstract

Conformal radiotherapy allows improvement in the treatment outcome due to increased targeting accuracy through advanced beam shaping techniques to precisely conform radiation dose to the geometry of the tumour. Treatment set-up and organ motion uncertainties are unavoidable factors that are limiting increases in accuracy and have to be accounted for in conformal treatment planning. The magnitudes of set-up errors and organ motion uncertainties for specific sites, and using various set-up techniques, have been quantified in the literature. However, the parameters used with these measurements and the presentation of the data has differed between studies for the same site. The purpose of this paper is to analyse and combine the published material into a uniform format and to display typical reported values of set-up and organ motion uncertainties. Values measured under similar conditions were averaged across studies. The results of this analysis illustrate (1) variability in the parameters used for measurements across studies, (2) typical motion ranges of the prostate, kidneys, liver and diaphragm, (3) typical means and standard deviations for set-up errors associated with the prostate, pelvis, brain, head and neck, thorax, rectum and breast and (4) a brief review of the common methods to lower or account for these uncertainties.

Entities:  

Mesh:

Year:  1999        PMID: 10474974

Source DB:  PubMed          Journal:  Australas Phys Eng Sci Med        ISSN: 0158-9938            Impact factor:   1.430


  12 in total

1.  Dosimetric impact of motion in free-breathing and gated lung radiotherapy: a 4D Monte Carlo study of intrafraction and interfraction effects.

Authors:  Joao Seco; Greg C Sharp; Ziji Wu; David Gierga; Florian Buettner; Harald Paganetti
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

Review 2.  Treatment planning optimisation in proton therapy.

Authors:  S E McGowan; N G Burnet; A J Lomax
Journal:  Br J Radiol       Date:  2013-01       Impact factor: 3.039

3.  Application of frozen Thiel-embalmed specimens for radiotherapy delineation guideline development: a method to create accurate MRI-enhanced CT datasets.

Authors:  Michael E J Stouthandel; Pim Pullens; Stephanie Bogaert; Max Schoepen; Carl Vangestel; Eric Achten; Liv Veldeman; Tom Van Hoof
Journal:  Strahlenther Onkol       Date:  2022-04-11       Impact factor: 4.033

4.  Reduced rectal toxicity with ultrasound-based image guided radiotherapy using BAT (B-mode acquisition and targeting system) for prostate cancer.

Authors:  Markus Bohrer; Peter Schröder; Grit Welzel; Hansjörg Wertz; Frank Lohr; Frederik Wenz; Sabine Kathrin Mai
Journal:  Strahlenther Onkol       Date:  2008-12-24       Impact factor: 3.621

5.  A comprehensive assessment by tumor site of patient setup using daily MVCT imaging from more than 3,800 helical tomotherapy treatments.

Authors:  Leah K Schubert; David C Westerly; Wolfgang A Tomé; Minesh P Mehta; Emilie T Soisson; Thomas R Mackie; Mark A Ritter; Deepak Khuntia; Paul M Harari; Bhudatt R Paliwal
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-03-15       Impact factor: 7.038

6.  Magnetic resonance imaging for adaptive cobalt tomotherapy: A proposal.

Authors:  Tomas Kron; David Eyles; L John Schreiner; Jerry Battista
Journal:  J Med Phys       Date:  2006-10

7.  Quality improvement process to assess tattoo alignment, set-up accuracy and isocentre reproducibility in pelvic radiotherapy patients.

Authors:  Kelly Elsner; Kate Francis; George Hruby; Stephanie Roderick
Journal:  J Med Radiat Sci       Date:  2014-11-21

8.  Assessment of setup uncertainties for various tumor sites when using daily CBCT for more than 2200 VMAT treatments.

Authors:  Young-Kee Oh; Jong-Geun Baek; Ok-Bae Kim; Jin-Hee Kim
Journal:  J Appl Clin Med Phys       Date:  2014-03-06       Impact factor: 2.102

9.  Tumor delineation: The weakest link in the search for accuracy in radiotherapy.

Authors:  C F Njeh
Journal:  J Med Phys       Date:  2008-10

10.  Computed tomography localization of radiation treatment delivery versus conventional localization with bony landmarks.

Authors:  Albert Y C Fung; S-Y Lisa Grimm; James R Wong; M Uematsu
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.