Literature DB >> 10470894

Percutaneous abdominal and pelvic interventional procedures using CT fluoroscopy guidance.

B Daly1, T L Krebs, J J Wong-You-Cheong, S S Wang.   

Abstract

OBJECTIVE: The purpose of our study was to assess the use of low-milliamperage CT fluoroscopy guidance for percutaneous abdominopelvic biopsy and therapeutic procedures.
MATERIALS AND METHODS: We reviewed the clinical records and relevant imaging studies of 97 patients who underwent 119 percutaneous CT fluoroscopy-guided abdominal or pelvic procedures: fluid collection aspiration or drainage catheter insertion (n = 59), biopsy (n = 49), hepatocellular carcinoma ethanol ablation (n = 6), chemoneurolysis (n = 4), and brachytherapy catheter insertion (n = 1). These procedures were guided using a helical CT scanner providing real-time fluoroscopy reconstruction at six frames per second. A control panel and video monitor beside the gantry allowed direct operator control during all interventional procedures.
RESULTS: One hundred twelve (94.1%) procedures were successfully performed using either a stand-off needle holder and continuous real-time CT fluoroscopy guidance or incremental manual insertion and intermittent CT fluoroscopy to confirm position. Image quality using low milliamperage was adequate for needle or drainage tube placement in all but two low-contrast liver lesions. Two hematomas were accessed but yielded no fluid on aspiration; one drainage procedure was abandoned after the patient developed endotoxic shock. Imaging of ethanol distribution during injection facilitated tumor ablation and neurolytic procedures. CT fluoroscopy allowed rapid assessment of needle, guidewire, dilator, and catheter placement, especially in nonaxial planes. Average CT fluoroscopy time for biopsy and therapeutic procedures was 133 sec (range, 35-336 sec) and 186 sec (range, 20-660 sec), respectively.
CONCLUSION: CT fluoroscopy is a practical clinical tool that facilitates effective performance of percutaneous abdominal and pelvic interventional procedures.

Entities:  

Mesh:

Year:  1999        PMID: 10470894     DOI: 10.2214/ajr.173.3.10470894

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  17 in total

1.  Robotically driven interventions: a method of using CT fluoroscopy without radiation exposure to the physician.

Authors:  Stephen B Solomon; Alexandru Patriciu; Mark E Bohlman; Louis R Kavoussi; Dan Stoianovici
Journal:  Radiology       Date:  2002-10       Impact factor: 11.105

2.  [CT fluoroscopy].

Authors:  P Rogalla; R Juran
Journal:  Radiologe       Date:  2004-07       Impact factor: 0.635

3.  Radiation dose reduction in computed tomography: techniques and future perspective.

Authors:  Lifeng Yu; Xin Liu; Shuai Leng; James M Kofler; Juan C Ramirez-Giraldo; Mingliang Qu; Jodie Christner; Joel G Fletcher; Cynthia H McCollough
Journal:  Imaging Med       Date:  2009-10

Review 4.  Approaches to the difficult drainage and biopsy.

Authors:  Shaunagh McDermott; Diane A Levis; Ronald S Arellano
Journal:  Semin Intervent Radiol       Date:  2012-12       Impact factor: 1.513

5.  Radiation dose and image quality of CT fluoroscopy with partial exposure mode.

Authors:  Keisuke Takiguchi; Atsushi Urikura; Tsukasa Yoshida; Yoshihiro Nakaya; Masahiro Endo; Takeshi Aramaki
Journal:  Diagn Interv Radiol       Date:  2020-07       Impact factor: 2.630

6.  Robotic needle insertion during computed tomography fluoroscopy-guided biopsy: prospective first-in-human feasibility trial.

Authors:  Takao Hiraki; Tetsushi Kamegawa; Takayuki Matsuno; Jun Sakurai; Toshiyuki Komaki; Takuya Yamaguchi; Koji Tomita; Mayu Uka; Yusuke Matsui; Toshihiro Iguchi; Hideo Gobara; Susumu Kanazawa
Journal:  Eur Radiol       Date:  2019-08-23       Impact factor: 5.315

7.  Evaluation of surface dose and image quality using the half-scan mode in chest computed tomography-guided interventional radiology: a phantom study.

Authors:  Hiroaki Hasegawa; Jiro Sato; Ikuo Kobayashi
Journal:  Radiol Phys Technol       Date:  2018-02-27

8.  Cone-beam computed tomography guidance with navigational overlay for percutaneous lung nodule biopsy.

Authors:  Giridhar M Shivaram; Anne Elizabeth Gill; Eric J Monroe; Kevin S H Koo; C Matthew Hawkins
Journal:  Pediatr Radiol       Date:  2018-11-08

9.  CT fluoroscopy-guided lung biopsy versus conventional CT-guided lung biopsy: a prospective controlled study to assess radiation doses and diagnostic performance.

Authors:  Ga Ram Kim; Jin Hur; Sang Min Lee; Hye-Jeong Lee; Yoo Jin Hong; Ji Eun Nam; Hua Sun Kim; Young Jin Kim; Byoung Wook Choi; Tae Hoon Kim; Kyu Ok Choe
Journal:  Eur Radiol       Date:  2010-08-22       Impact factor: 5.315

10.  Clinical feasibility and usefulness of CT fluoroscopy-guided percutaneous transhepatic biliary drainage in emergency patients with acute obstructive cholangitis.

Authors:  Ji Hyung Kim
Journal:  Korean J Radiol       Date:  2009-03-03       Impact factor: 3.500

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.