Time-course of impairment of respiratory mechanics after cardiac surgery and cardiopulmonary bypass.

V M Ranieri1, N Vitale, S Grasso, F Puntillo, L Mascia, D Paparella, P Tunzi, R Giuliani, L de Luca Tupputi, T Fiore.   

Abstract

OBJECTIVE: Cardiopulmonary bypass (CPB) is associated with abnormalities of lung function characterized by an increase in static elastance of the respiratory system. We examined the following: a) the effects of CPB on the total inspiratory volume-pressure (V-P) relationship of the respiratory system; b) the relative contribution of the chest wall and lung to the impairment of respiratory system mechanics; and c) the time-course of such impairment.
DESIGN: Prospective, interventional study.
SETTING: Surgical and medical intensive care units in a teaching hospital. PATIENTS: Eight adult patients scheduled for elective open heart surgery to correct valvular dysfunction.
INTERVENTIONS: V-P curves (interrupter technique) of the respiratory system were partitioned between the chest wall and lung by measurements of esophageal pressure. Measurements were obtained before sternotomy (control), immediately after, 4 hrs after, and 7 hrs after separation from CPB.
MEASUREMENTS AND MAIN RESULTS: Control V-P relationships of the respiratory system and lung showed lower inflection points (Pflex) at pressure values of 5.9+/-2.3 and 4.3+/-2.5 cm H2O, respectively. Immediately after and 4 hrs after separation from CPB, both curves had sigmoid shapes because of lower Pflex and formation of upper inflection (UIP) points. The pressures corresponding to the Pflex increased significantly (p < .001) by 56%+/-3% and 78%+/-4%, whereas the UIP corresponded to a pressure value of 42.34+/-8.5 and 35.6+/-7.8 cm H2O in the respiratory system and lung, respectively. A linear V-P relationship of the chest wall was observed during the control condition and after separation from CPB. Four hours later, no further increases in the pressure values corresponding to Pflex were observed on the inspiratory V-P curves of the respiratory system and lung, whereas the UIP occurred at a pressure of 35.6+/-9.1 and 29.7+/-8.4 cm H2O, respectively. A UIP was present on the V-P curve of the chest wall at a volume of 0.77+/-0.02 L. Seven hours after separation from CPB, the inspiratory V-P curves of the respiratory system, chest wall, and lung returned to normal.
CONCLUSIONS: Sternotomy and CPB produced immediate changes in lung mechanics. Chest wall mechanics were affected only 4 hrs after sternotomy. Seven hours after disconnection from CPB, all mechanics had returned to normal.

Entities:  

Mesh:

Year:  1999        PMID: 10470749     DOI: 10.1097/00003246-199908000-00008

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  8 in total

1.  Respiratory function after aortic aneurysm repair: a comparison between retroperitoneal and transperitoneal approaches.

Authors:  Carlo A Volta; Enrico Ferri; Elisabetta Marangoni; Riccardo Ragazzi; Marco Verri; Valentina Alvisi; Silvia Zardi; Sara Bertacchini; Gaetano Gritti; Raffaele Alvisi
Journal:  Intensive Care Med       Date:  2003-06-26       Impact factor: 17.440

2.  Off-pump coronary revascularization: A potential benefit for female patients?

Authors:  Ahmed A Arifi; Erica Huen; J G Franke; Hani Najm
Journal:  J Saudi Heart Assoc       Date:  2009-10

Review 3.  Pulmonary pathophysiology and lung mechanics in anesthesiology: a case-based overview.

Authors:  Marcos F Vidal Melo; Guido Musch; David W Kaczka
Journal:  Anesthesiol Clin       Date:  2012-09-01

Review 4.  Postoperative pulmonary dysfunction and mechanical ventilation in cardiac surgery.

Authors:  Rafael Badenes; Angels Lozano; F Javier Belda
Journal:  Crit Care Res Pract       Date:  2015-02-03

5.  Physiological Correlation of Airway Pressure and Transpulmonary Pressure Stress Index on Respiratory Mechanics in Acute Respiratory Failure.

Authors:  Chun Pan; Lu Chen; Yun-Hang Zhang; Wei Liu; Rosario Urbino; V Marco Ranieri; Hai-Bo Qiu; Yi Yang
Journal:  Chin Med J (Engl)       Date:  2016-07-20       Impact factor: 2.628

6.  Accuracy of chest auscultation in detecting abnormal respiratory mechanics in the immediate postoperative period after cardiac surgery.

Authors:  Glaciele Xavier; César Augusto Melo-Silva; Carlos Eduardo Ventura Gaio Dos Santos; Veronica Moreira Amado
Journal:  J Bras Pneumol       Date:  2019-07-29       Impact factor: 2.624

7.  Post-cardiopulmonary bypass hypoxaemia in paediatric patients undergoing congenital heart disease surgery: risk factors, features, and postoperative pulmonary complications.

Authors:  Yuan Sun; Xiao-Ming Deng; Ying Cai; Sai-E Shen; Li-Ya Dong
Journal:  BMC Cardiovasc Disord       Date:  2022-09-30       Impact factor: 2.174

8.  Soluble isoform of the receptor for advanced glycation end products as a biomarker for postoperative respiratory failure after cardiac surgery.

Authors:  Tokujiro Uchida; Nagara Ohno; Miho Asahara; Yoshitsugu Yamada; Osamu Yamaguchi; Makoto Tomita; Koshi Makita
Journal:  PLoS One       Date:  2013-07-23       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.