| Literature DB >> 31365614 |
Glaciele Xavier1,2, César Augusto Melo-Silva1,3, Carlos Eduardo Ventura Gaio Dos Santos1,4, Veronica Moreira Amado1,4.
Abstract
OBJECTIVE: To investigate the accuracy of chest auscultation in detecting abnormal respiratory mechanics.Entities:
Mesh:
Year: 2019 PMID: 31365614 PMCID: PMC6715162 DOI: 10.1590/1806-3713/e20180032
Source DB: PubMed Journal: J Bras Pneumol ISSN: 1806-3713 Impact factor: 2.624
Figure 1Study design. Cst,rs: static compliance of the respiratory system; and R,rs: respiratory system resistance.
Cardiac surgery procedures and patient respiratory comorbidities.
| Variable | (N = 200) |
|---|---|
| Cardiac surgery procedures, n (%) | |
| Myocardial revascularization | 139 (69.5) |
| Heart valve replacement | 50 (25.0) |
| Aortic repair | 5 (2.5) |
| Atrial septal repair | 3 (1.5) |
| Heart valve repair | 2 (1.0) |
| Intracardiac tumor resection | 1 (0.5) |
| Respiratory comorbidities, n (%) | |
| None | 141 (70.5) |
| Nicotine addiction | 52 (26.0) |
| COPD | 5 (2.5) |
| Tuberculosis sequelae | 2 (1.0) |
Figure 2A and B: static compliance of the respiratory system (Cst,rs); C and D: respiratory system resistance (R,rs). Open circles represent individual values of Cst,rs and R,rs; open diamonds represent individual values of Cst,rs and R,rs when examiners classified chest auscultation as normal; open triangles represent individual values of Cst,rs and R,rs when examiners classified chest auscultation as abnormal; dotted horizontal lines mark the cut-off values for Cst,rs (≥ 60 mL/cmH2O) and R,rs (≤ 15 cmH2O/L/s); and solid horizontal lines are the mean Cst,rs and R,rs values for each chest auscultation classification.
Association between sounds related to the lung parenchyma or chest wall and static compliance of the respiratory system.
| Variable | Cst,rs (mL/cmH2O) | p | ϕ | ϕ | ||
|---|---|---|---|---|---|---|
| < 60 | ≥ 60 | |||||
| (n) | (n) | |||||
| Decreased breath sounds, abolished breath sounds, or crackles | Examiner A | |||||
| Yes | 40 | 13 | 0.39 | 0.03 | 0.66 | |
| No | 119 | 28 | ||||
| Examiner B | ||||||
| Yes | 58 | 15 | 0.99 | 0 | 0.99 | |
| No | 101 | 26 | ||||
Cst,rs: static compliance of the respiratory system; and ϕ: phi coefficient.
Association between airway-related sounds and respiratory system resistance.
| Variable | R,rs (cmH2O/L/s) | p | ϕ | ϕ | ||
|---|---|---|---|---|---|---|
| ≥ 15 | < 15 | |||||
| (n) | (n) | |||||
| Rhonchi or wheezing | Examiner A | |||||
| Yes | 6 | 7 | < 0.01a | 0.31 | < 0.01 | |
| No | 14 | 173 | ||||
| Examiner B | ||||||
| Yes | 2 | 12 | 0.63a | 0.03 | 0.57 | |
| No | 18 | 168 | ||||
R,rs: respiratory system resistance; and ϕ: phi coefficient. aFisher’s exact test.
Accuracy, sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio for chest auscultation in detecting abnormal respiratory mechanics.
| Examiner | Accuracy | Sensitivity | Specificity | LR+ | LR− |
|---|---|---|---|---|---|
| Variable | (%) | % (95% CI) | % (95% CI) | Ratio (95% CI) | Ratio (95% CI) |
| A | |||||
| Decreased breath sounds, abolished breath sounds, or crackles | 34.0 | 25.2 (21.5-28.3) | 68.3 (54.1-80.6) | 0.8 (0.4-1.4) | 1.1 (0.9-1.4) |
| Rhonchi or wheezing | 89.5 | 30.0 (13.9-46.7) | 96.1 (94.3-98) | 7.7 (2.4-22.8) | 0.7 (0.5-0.9) |
| B | |||||
| Decreased breath sounds, abolished breath sounds, or crackles | 42.0 | 10.0 (1.8-28.6) | 93.3 (92.4-95.4) | 0.9 (0.6-1.7) | 1.0 (0.7-1.3) |
| Rhonchi or wheezing | 85.0 | 79.5 (71.2-86.2) | 20.5 (15.7-24.7) | 1.5 (0.2-6.2) | 0.9 (0.7-1.0) |
LR+: positive likelihood ratio; and LR−: negative likelihood ratio.