Literature DB >> 10463650

Magnetic resonance T2* measurements of the normal human lung in vivo with ultra-short echo times.

K W Stock1, Q Chen, H Hatabu, R R Edelman.   

Abstract

The objective of this study was to measure T2* values of the normal human lung in vivo during breathhold using a rapid gradient-echo sequence with ultra-short echo times (TE). A sagittal slice of the right lung was imaged in six volunteers with various TE ranging from 0.5 ms to 5 ms using a clinical 1.5 Tesla MR scanner. T2* values were calculated in a region of interest in the dependent and non-dependent lung. In the dependent lung, T2* values of 1.1 ms+/-0.15 ms were measured, and in the non-dependent lung, 0.86 ms+/-0.11 (p < 0.01). T2* measurements of the normal human lung during breathhold are feasible with a clinical MR unit. The short T2* values require the use of very short TE times (< 2.5 ms) in gradient-echo sequences to obtain adequate signal intensity from lung tissue.

Entities:  

Mesh:

Year:  1999        PMID: 10463650     DOI: 10.1016/s0730-725x(99)00047-8

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  20 in total

1.  Feasibility of combining MR perfusion, angiography, and 3He ventilation imaging for evaluation of lung function in a porcine model.

Authors:  Cheng Hong; Jason C Leawoods; Dmitriy A Yablonskiy; John R Leyendecker; Kyongtae T Bae; Thomas K Pilgram; Pamela K Woodard; Mark S Conradi; Jie Zheng
Journal:  Acad Radiol       Date:  2005-02       Impact factor: 3.173

2.  Lung liquid clearance in preterm lambs assessed by magnetic resonance imaging.

Authors:  Ali Houeijeh; Pierre Tourneux; Sébastien Mur; Estelle Aubry; Romain Viard; Dyuti Sharma; Laurent Storme
Journal:  Pediatr Res       Date:  2017-02-07       Impact factor: 3.756

3.  T2 mapping of CT remodelling patterns in interstitial lung disease.

Authors:  Maria T A Buzan; Monika Eichinger; Michael Kreuter; Hans-Ulrich Kauczor; Felix J Herth; Arne Warth; Carmen Monica Pop; Claus Peter Heussel; Julien Dinkel
Journal:  Eur Radiol       Date:  2015-06-03       Impact factor: 5.315

4.  Measuring lung water: ex vivo validation of multi-image gradient echo MRI.

Authors:  Sebastiaan Holverda; Rebecca J Theilmann; Rui C Sá; Tatsuya J Arai; Evan T Hall; David J Dubowitz; G Kim Prisk; Susan R Hopkins
Journal:  J Magn Reson Imaging       Date:  2011-07       Impact factor: 4.813

5.  Retrospective respiratory self-gating and removal of bulk motion in pulmonary UTE MRI of neonates and adults.

Authors:  Nara S Higano; Andrew D Hahn; Jean A Tkach; Xuefeng Cao; Laura L Walkup; Robert P Thomen; Stephanie L Merhar; Paul S Kingma; Sean B Fain; Jason C Woods
Journal:  Magn Reson Med       Date:  2016-03-12       Impact factor: 4.668

6.  Diffusion Weighted Magnetic Resonance Imaging for the Characterization of Solitary Pulmonary Lesions.

Authors:  Çağlayan Çakır; Hakan Gençhellaç; Osman Temizöz; Ahmet Polat; Ersin Şengül; Gökhan Duygulu
Journal:  Balkan Med J       Date:  2015-10-01       Impact factor: 2.021

Review 7.  Hyperpolarized 129Xe MRI of the human lung.

Authors:  John P Mugler; Talissa A Altes
Journal:  J Magn Reson Imaging       Date:  2013-02       Impact factor: 4.813

8.  Optimized 3D ultrashort echo time pulmonary MRI.

Authors:  Kevin M Johnson; Sean B Fain; Mark L Schiebler; Scott Nagle
Journal:  Magn Reson Med       Date:  2012-12-04       Impact factor: 4.668

Review 9.  [T1 maps and O2-enhanced MRT of the diseased lung. Emphysema, fibrosis, mucoviscidosis].

Authors:  A Stadler; L Stiebellehner; P M Jakob; J F T Arnold; A A Bankier
Journal:  Radiologe       Date:  2006-04       Impact factor: 0.635

10.  Quantitative MRI measurement of lung density must account for the change in T(2) (*) with lung inflation.

Authors:  Rebecca J Theilmann; Tatsuya J Arai; Ahsan Samiee; David J Dubowitz; Susan R Hopkins; Richard B Buxton; G Kim Prisk
Journal:  J Magn Reson Imaging       Date:  2009-09       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.