Clinical use of ultrasound tissue harmonic imaging.

F Tranquart1, N Grenier, V Eder, L Pourcelot.   

Abstract

The recent introduction of tissue harmonic imaging could resolve the problems related to ultrasound in technically difficult patients by providing a marked improvement in image quality. Tissue harmonics are generated during the transmit phase of the pulse-echo cycle, that is, while the transmitted pulse propagates through tissue. Tissue harmonic images are formed by utilizing the harmonic signals that are generated by tissue and by filtering out the fundamental echo signals that are generated by the transmitted acoustic energy. To achieve this, two processes could be used; one by using filters for fundamental and harmonic imaging and the second using two simultaneous pulses with a 180 degrees difference in phase. The introduction of harmonics allows increased penetration without a loss of detail, by obtaining a clearer image at depth with significantly less compromise to the image quality caused by the use of lower frequencies. This imaging mode could be used in different organs with a heightening of low-contrast lesions through artefact reduction, as well as by the induced greater intrinsic contrast sensitivity of the harmonic imaging mode.

Entities:  

Mesh:

Year:  1999        PMID: 10461715     DOI: 10.1016/s0301-5629(99)00060-5

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  50 in total

Review 1.  [Advances in pediatric sonography].

Authors:  K Darge; M Beer
Journal:  Radiologe       Date:  2003-10       Impact factor: 0.635

2.  Improved Shear Wave Motion Detection Using Pulse-Inversion Harmonic Imaging With a Phased Array Transducer.

Authors:  Matthew W Urban; Armando Manduca; Sorin V Pislaru; Randall R Kinnick; Cristina Pislaru; James F Greenleaf
Journal:  IEEE Trans Med Imaging       Date:  2013-09-05       Impact factor: 10.048

3.  [Modern ultrasound technologies and their application in pediatric urinary tract imaging].

Authors:  K Darge; A Heidemeier
Journal:  Radiologe       Date:  2005-12       Impact factor: 0.635

4.  Mechanical and clinical performance of pulse-inversion tissue harmonic imaging in the superficial region.

Authors:  Chieko Sugawara; Akira Takahashi
Journal:  J Med Ultrason (2001)       Date:  2010-03-18       Impact factor: 1.314

5.  Enhanced axial and lateral resolution using stabilized pulses.

Authors:  Shujie Chen; Kevin J Parker
Journal:  J Med Imaging (Bellingham)       Date:  2017-05-08

6.  Sonographic classification of testicular tumors by tissue harmonic imaging: experience of 58 cases.

Authors:  Atsuo Kawamoto; Tadashi Hatano; Kazuhiro Saito; Rie Inoue; Toshitaka Nagao; Shigeru Sanada
Journal:  J Med Ultrason (2001)       Date:  2017-03-20       Impact factor: 1.314

7.  Harmonic versus conventional ultrasound imaging of the urinary tract in children.

Authors:  Ulrike Bartram; Kassa Darge
Journal:  Pediatr Radiol       Date:  2005-03-05

8.  Quantitative assessment of the magnitude, impact and spatial extent of ultrasonic clutter.

Authors:  Muyinatu A Lediju; Michael J Pihl; Jeremy J Dahl; Gregg E Trahey
Journal:  Ultrason Imaging       Date:  2008-07       Impact factor: 1.578

9.  Diagnosis of vesicoureteric reflux with low-dose contrast-enhanced harmonic ultrasound imaging.

Authors:  Kassa Darge; Richard-Tobias Moeller; Andreas Trusen; Felix Butter; Nader Gordjani; Hubertus Riedmiller
Journal:  Pediatr Radiol       Date:  2004-09-22

10.  Preliminary Results on the Feasibility of Using ARFI/SWEI to Assess Cutaneous Sclerotic Diseases.

Authors:  Seung Yun Lee; Adela R Cardones; Joshua Doherty; Kathryn Nightingale; Mark Palmeri
Journal:  Ultrasound Med Biol       Date:  2015-08-08       Impact factor: 2.998

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.