Literature DB >> 10457581

Anatomic evaluation of two different techniques for the percutaneous insertion of pedicle screws in the lumbar spine.

L Wiesner1, R Kothe, W Rüther.   

Abstract

STUDY
DESIGN: An in vitro study in which a human cadaver model was used to examine the accuracy of two different techniques of percutaneous pedicle screw insertion in the lumbar spine.
OBJECTIVES: To investigate the in vitro misplacement rate of pedicle screw insertion for two different percutaneous techniques: 1) the well established Magerl technique, and 2) a new modified technique. SUMMARY OF BACKGROUND DATA: Numerous anatomic and biomechanical studies have been conducted to analyze the in vitro and in vivo characteristics of pedicle screw insertion in the lumbar spine via an open approach, whereas there is a lack of experimental data concerning the more sophisticated percutaneous procedure.
METHODS: Thirty human specimens from L1 to S1 were separated into two groups (A and B). In group A, the screws were placed in accordance with the technique described by Magerl; in group B, a new modified technique developed by the authors' research group was used. After screw placement, the specimens were dissected, and pedicle violations were noted with respect to the degree and direction of the screw misplacement.
RESULTS: The dissection of the specimens showed that of 360 pedicle screws, 37 were misplaced. This finding translates into an overall misplacement rate of 10%. With the Magerl technique, 23 pedicle violations (misplacement rate, 13%) were found; with the modified technique, only 14 dislocated pedicle screws (misplacement rate, 8%) were detected. This difference was not statistically significant (P = 0.118). In both groups, there were significantly more medical pedicle violations than lateral (32 medial and 5 lateral screw dislocations). The degree of the screw misplacements varied between 1.0 and 5.0 mm. The majority of pedicle violations (30 of 37) were minor, i.e., less than 3.0 mm.
CONCLUSIONS: This in vitro study showed that the percutaneous technique of pedicle screw insertion in the lumbar spine is a safe and reliable procedure. Compared with the well-established Magerl technique, the new modified technique did not decrease the misplacement rate significantly, although less pedicle violations were found in the upper lumbar spine.

Entities:  

Mesh:

Year:  1999        PMID: 10457581     DOI: 10.1097/00007632-199908010-00015

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  36 in total

1.  Minimal-invasive stabilization and circumferential spinal cord decompression in metastatic epidural spinal cord compression (MESCC).

Authors:  Nils Hansen-Algenstaedt; Reginald Knight; Jörg Beyerlein; Roland Gessler; Lothar Wiesner; Christian Schaefer
Journal:  Eur Spine J       Date:  2013-09       Impact factor: 3.134

Review 2.  Robot-assisted and fluoroscopy-guided pedicle screw placement: a systematic review.

Authors:  Hani J Marcus; Thomas P Cundy; Dipankar Nandi; Guang-Zhong Yang; Ara Darzi
Journal:  Eur Spine J       Date:  2013-06-26       Impact factor: 3.134

3.  Comparison of open versus percutaneous pedicle screw insertion in a sheep model.

Authors:  W Lehmann; A Ushmaev; A Ruecker; J Nuechtern; L Grossterlinden; P G Begemann; T Baeumer; J M Rueger; D Briem
Journal:  Eur Spine J       Date:  2008-04-04       Impact factor: 3.134

4.  Factors affecting the accurate placement of percutaneous pedicle screws during minimally invasive transforaminal lumbar interbody fusion.

Authors:  Moon-Chan Kim; Hung-Tae Chung; Jae-Lim Cho; Dong-Jun Kim; Nam-Su Chung
Journal:  Eur Spine J       Date:  2011-07-01       Impact factor: 3.134

5.  Computer tomography assessment of pedicle screw placement in lumbar and sacral spine: comparison between free-hand and O-arm based navigation techniques.

Authors:  J Silbermann; F Riese; Y Allam; T Reichert; H Koeppert; M Gutberlet
Journal:  Eur Spine J       Date:  2011-01-21       Impact factor: 3.134

6.  Technical Report of Free Hand Pedicle Screw Placement using the Entry Points with Junction of Proximal Edge of Transverse Process and Lamina in Lumbar Spine: Analysis of 2601 Consecutive Screws.

Authors:  Chang Hyun Oh; Seung Hwan Yoon; Yongjung J Kim; Dongkeun Hyun; Hyeong-Chun Park
Journal:  Korean J Spine       Date:  2013-03-31

7.  Computer tomography assessment of pedicle screw placement in thoracic spine: comparison between free hand and a generic 3D-based navigation techniques.

Authors:  Yasser Allam; J Silbermann; F Riese; R Greiner-Perth
Journal:  Eur Spine J       Date:  2012-09-25       Impact factor: 3.134

8.  Minimal-invasive TLIF.

Authors:  Nils Hansen-Algenstaedt; Melanie Liem; SalahAddeen O Khalifah; Ansgar Ilg; Alf Giese
Journal:  Eur Spine J       Date:  2016-12       Impact factor: 3.134

9.  MIS revision of de novo scoliosis and stenosis, following open spinal instrumentation.

Authors:  Nils Hansen-Algenstaedt; SalahAddeen Khalifah; Melanie Liem; Johannes Holz; Alf Giese
Journal:  Eur Spine J       Date:  2016-12       Impact factor: 3.134

10.  Thoracoscopically assisted corpectomy and percutaneous transpedicular instrumentation in management of burst thoracic and thoracolumbar fractures.

Authors:  Ahmed Shawky; Al-Moataz Abdel Razek Zohny Al-Sabrout; Mohamed El-Meshtawy; Khaled Mohamed Hasan; Heinrich Boehm
Journal:  Eur Spine J       Date:  2013-05-21       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.