Literature DB >> 10456374

Gradiometer pick-up coil design for a low field SQUID-MRI system.

H C Seton1, J M Hutchison, D M Bussell.   

Abstract

We describe the use of liquid helium-cooled (4.2 K) gradiometer coils and a DC superconducting quantum interference device (SQUID) preamplifier to improve the SNR of magnetic resonance imaging (MRI) at 0.01 T. Gradiometer windings are used both to reduce lossy interactions with the MRI system's room temperature magnet and gradient coils and also to reject interference from more distant sources, which reduces the need for RF shielding. We have tested both axial and planar (figure-of-eight) gradiometer configurations. The figure-of-eight gradiometer has a more rapid fall-off in sensitivity with increasing distance from its windings than the axial gradiometer, but this is compensated for by reduced lossy interactions and improved interference rejection. We have used the system to image the human arm.

Entities:  

Mesh:

Year:  1999        PMID: 10456374     DOI: 10.1007/bf02590528

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  7 in total

1.  Fast recovery, high sensitivity NMR probe and preamplifier for low frequencies.

Authors:  D I Hoult
Journal:  Rev Sci Instrum       Date:  1979-02       Impact factor: 1.523

2.  Use of high temperature superconductor in a receiver coil for magnetic resonance imaging.

Authors:  A S Hall; N M Alford; T W Button; D J Gilderdale; K A Gehring; I R Young
Journal:  Magn Reson Med       Date:  1991-08       Impact factor: 4.668

3.  Surface and gradiometer coils near a conducting body: the lift-off effect.

Authors:  B H Suits; A N Garroway; J B Miller
Journal:  J Magn Reson       Date:  1998-12       Impact factor: 2.229

4.  Sample noise with circular surface coils.

Authors:  M D Harpen
Journal:  Med Phys       Date:  1987 Jul-Aug       Impact factor: 4.071

5.  A high-temperature superconducting receiver for nuclear magnetic resonance microscopy.

Authors:  R D Black; T A Early; P B Roemer; O M Mueller; A Mogro-Campero; L G Turner; G A Johnson
Journal:  Science       Date:  1993-02-05       Impact factor: 47.728

6.  Novel approaches to low-cost MRI.

Authors:  A Macovski; S Conolly
Journal:  Magn Reson Med       Date:  1993-08       Impact factor: 4.668

7.  Thin film high temperature superconducting RF coils for low field MRI.

Authors:  J G van Heteren; T W James; L C Bourne
Journal:  Magn Reson Med       Date:  1994-09       Impact factor: 4.668

  7 in total
  5 in total

1.  Versatile coil design and positioning of transverse-field RF surface coils for clinical 1.5-T MRI applications.

Authors:  M Alfonsetti; V Clementi; S Iotti; G Placidi; R Lodi; B Barbiroli; A Sotgiu; M Alecci
Journal:  MAGMA       Date:  2004-12-30       Impact factor: 2.310

2.  Construction of a three-dimensional outline of the heart and conduction pathway by means of a 64-channel magnetocardiogram in patients with atrial flutter and fibrillation.

Authors:  Riccardo Fenici
Journal:  Int J Cardiovasc Imaging       Date:  2005-10       Impact factor: 2.357

3.  MRI of the human brain at 130 microtesla.

Authors:  Ben Inglis; Kai Buckenmaier; Paul Sangiorgio; Anders F Pedersen; Matthew A Nichols; John Clarke
Journal:  Proc Natl Acad Sci U S A       Date:  2013-11-19       Impact factor: 11.205

4.  SQUID-based detection of ultra-low-field multinuclear NMR of substances hyperpolarized using signal amplification by reversible exchange.

Authors:  K Buckenmaier; M Rudolph; C Back; T Misztal; U Bommerich; P Fehling; D Koelle; R Kleiner; H A Mayer; K Scheffler; J Bernarding; M Plaumann
Journal:  Sci Rep       Date:  2017-10-18       Impact factor: 4.379

5.  Fast Room Temperature Very Low Field-Magnetic Resonance Imaging System Compatible with MagnetoEncephaloGraphy Environment.

Authors:  Angelo Galante; Raffaele Sinibaldi; Allegra Conti; Cinzia De Luca; Nadia Catallo; Piero Sebastiani; Vittorio Pizzella; Gian Luca Romani; Antonello Sotgiu; Stefania Della Penna
Journal:  PLoS One       Date:  2015-12-02       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.