Literature DB >> 10450839

A prospective comparison of brain contrast characteristics and lesion detection using single-shot fast spin-echo and fast spin-echo.

T K Mittal1, S F Halpin, M W Bourne, M D Hourihan, T Perkins, Y Sun, S Tan.   

Abstract

MRI is limited by movement artefact, even with current imagers, when examining a restless or claustrophobic patient. We prospectively analysed the images of 92 patients produced by a single-shot fast spin-echo (SSFSE) pulse sequence and compared them with conventional (FSE) and reduced-time fast spin-echo (RT-FSE) techniques, with regard to lesion detection and movement artefact in brain imaging. Images obtained in each case were independently reviewed and scored for overall diagnosis, number of lesions detected, and movement artefact. FSE showed 1217 lesions, RT-FSE 1137, and SSFSE 1044. This discrepancy arose mainly in patients with multiple sclerosis or small-vessel disease, since with SSFSE we were less able to separate small, adjacent low-contrast lesions than with FSE. Arbitrary movement scores were 36, 25 and zero respectively. There were, however, no clinically significant differences in overall diagnosis between the three techniques. SSFSE thus proved a reliable, fast, accurate method for obtaining T2-weighted images, and may be of particular use in the restless, claustrophobic or obtunded patient.

Entities:  

Mesh:

Year:  1999        PMID: 10450839     DOI: 10.1007/s002340050787

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  4 in total

1.  T2-weighted balanced steady-state free procession MRI evaluated for diagnosing placental adhesion disorder in late pregnancy.

Authors:  Ang Yang; Xue Hong Xiao; Zhi Long Wang; Ze Yan Wang; Ke Yi Wang
Journal:  Eur Radiol       Date:  2018-04-12       Impact factor: 5.315

2.  Performance of PROPELLER relative to standard FSE T2-weighted imaging in pediatric brain MRI.

Authors:  A Talia Vertinsky; Erika Rubesova; Michael V Krasnokutsky; Sabine Bammer; Jarrett Rosenberg; Allan White; Patrick D Barnes; Roland Bammer
Journal:  Pediatr Radiol       Date:  2009-08-11

3.  Use of computed tomography and diffusion weighted imaging in children with ventricular shunt.

Authors:  Altan Gunes; Ibrahim Halil Oncel; Serra Ozbal Gunes; Ahmet Ziya Birbilen; Sahin Hanalioglu
Journal:  Childs Nerv Syst       Date:  2019-01-08       Impact factor: 1.475

4.  Brain imaging in the unsedated pediatric patient: comparison of periodically rotated overlapping parallel lines with enhanced reconstruction and single-shot fast spin-echo sequences.

Authors:  Kirsten P Forbes; James G Pipe; John P Karis; Victoria Farthing; Joseph E Heiserman
Journal:  AJNR Am J Neuroradiol       Date:  2003-05       Impact factor: 3.825

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.