Literature DB >> 10450684

Factors affecting 131I-Lym-1 pharmacokinetics and radiation dosimetry in patients with non-Hodgkin's lymphoma and chronic lymphocytic leukemia.

G L DeNardo1, S J DeNardo, S Shen, D A DeNardo, G R Mirick, D J Macey, K R Lamborn.   

Abstract

UNLABELLED: Lym-1, a monoclonal antibody that preferentially targets malignant lymphocytes, has induced therapeutic responses in patients with non-Hodgkin's lymphoma (NHL) and chronic lymphocytic leukemia (CLL) when labeled with 131I. Responders had statistically significant prolongation of survival compared with nonresponders. The nonmyeloablative, maximum tolerated dose for each of two doses of 131I-Lym-1 was 3.7 GBq/m2 (total 7.4 GBq/m2 [100 mCi/m2, total 200 mCi/m2]) of body surface area. The purpose of this study was to determine the pharmacokinetics and radiation dosimetry for the initial 131I-Lym-1 therapy dose in patients with NHL and CLL and to compare tumor dosimetry with 131I-Lym-1 dosing and other patient parameters.
METHODS: Fifty-one patients with stage 3 or 4 lymphoma were treated with 131I-Lym-1 (0.74-8.04 GBq [20-217 mCi]) in either a maximum tolerated dose (MTD) or low-dose (LD) trial. Total Lym-1 given to each patient was sufficient in all instances to exceed the threshold required for stable pharmacokinetics. Quantitative imaging and physical examination, including caliper and CT measurement of tumor size and analysis of blood, urine and feces, were performed for a period of 7 to 10 d after infusion to assess pharmacokinetics and radiation dosimetry. Clinical records were reviewed to obtain data required for comparative assessments.
RESULTS: The concentration (%ID/g) and biologic half-time of 131-Lym-1 in tumor were about twice those in normal tissues, although tumor half-time was similar to that of the thyroid. Pharmacokinetics were similar for patients in the MTD and LD trials, and for NHL and CLL patients in the LD trial, except that the latter group had less tumor concentration of 131I. Mean tumor radiation dose per unit of administered 131I was 1.0 Gy/GBq (3.7 rad/mCi) for patients with NHL whether in MTD or LD trials, about nine times greater than that for body or marrow. Tumor radiation dose was less and liver radiation dose was more in patients with CLL. Otherwise, radiation dosimetry was, on average, remarkably similar among groups of patients and among individual patients. Pharmacokinetics and dosimetry did not appear to be influenced by the amount of 131I or Lym-1 within the ranges administered. Tumor concentration of 131I and radiation dose per gigabecquerel were inversely related to tumor size but did not seem to be related to histologic grade or type, tumor burden or therapeutic response.
CONCLUSION: The therapeutic index of 131I-Lym-1 was favorable, although the index for patients with CLL was less than that for patients with NHL. Pharmacokinetics and radiation dosimetry were, on average, remarkably similar among patients and groups of patients in different trials.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10450684

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  6 in total

1.  131I-tositumomab radioimmunotherapy: initial tumor dose-response results using 3-dimensional dosimetry including radiobiologic modeling.

Authors:  Yuni K Dewaraja; Matthew J Schipper; Peter L Roberson; Scott J Wilderman; Hanan Amro; Denise D Regan; Kenneth F Koral; Mark S Kaminski; Anca M Avram
Journal:  J Nucl Med       Date:  2010-06-16       Impact factor: 10.057

2.  Accurate dosimetry in 131I radionuclide therapy using patient-specific, 3-dimensional methods for SPECT reconstruction and absorbed dose calculation.

Authors:  Yuni K Dewaraja; Scott J Wilderman; Michael Ljungberg; Kenneth F Koral; Kenneth Zasadny; Mark S Kaminiski
Journal:  J Nucl Med       Date:  2005-05       Impact factor: 10.057

3.  Improving the treatment of non-Hodgkin lymphoma with antibody-targeted radionuclides.

Authors:  Robert M Sharkey; Habibe Karacay; David M Goldenberg
Journal:  Cancer       Date:  2010-02-15       Impact factor: 6.860

4.  Pretreatment CLR 124 Positron Emission Tomography Accurately Predicts CLR 131 Three-Dimensional Dosimetry in a Triple-Negative Breast Cancer Patient.

Authors:  Abigail E Besemer; Joseph J Grudzinski; Jamey P Weichert; Lance T Hall; Bryan P Bednarz
Journal:  Cancer Biother Radiopharm       Date:  2018-10-23       Impact factor: 3.099

5.  Targeted radionuclide therapy.

Authors:  Lawrence E Williams; Gerald L DeNardo; Ruby F Meredith
Journal:  Med Phys       Date:  2008-07       Impact factor: 4.071

6.  Use of integrated SPECT/CT imaging for tumor dosimetry in I-131 radioimmunotherapy: a pilot patient study.

Authors:  Yuni K Dewaraja; Scott J Wilderman; Kenneth F Koral; Mark S Kaminski; Anca M Avram
Journal:  Cancer Biother Radiopharm       Date:  2009-08       Impact factor: 3.099

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.