Literature DB >> 10447175

Augmentation of distal radius fracture fixation with coralline hydroxyapatite bone graft substitute.

S W Wolfe1, L Pike, J F Slade, L D Katz.   

Abstract

We implanted coralline hydroxyapatite bone graft as a substitute for autogenous bone graft to support the reduced articular surface of 21 consecutive patients with distal radius fractures treated with external fixation and K-wires. The purpose of this single-cohort retrospective study was to report the outcomes of treatment with this material, complications associated with its use, and its efficacy in supporting the articular surface reduction. Eighteen patients were available for independent evaluation of motion, subjective outcome analysis, and final radiographic analysis at an average of 35 months after surgery. Wrist motion averaged 90% of the uninjured wrist and grip strength measured 75% of the uninjured side. Results in 17 of the 18 cases were rated as good or excellent by the criteria of Gartland and Werley; 12 by the criteria of Green and O'Brien. Seventeen had good or excellent radiographic results by the modified Lidstrom radiographic scoring system. The average DASH functional/symptom score was 90.3 (maximum, 100). Radiographic parameters were restored to an average of 12 mm radial length, 4 degrees volar tilt, 23 degrees radial inclination, and 0.6 mm positive ulnar variance. Articular reduction was maintained in all patients. A complication related to the use of coral was a 0.5 mm prominence of coralline hydroxyapatite beyond the subchondral line at the radiocarpal joint in 1 patient, which was not present on final radiographs. Coralline hydroxyapatite was effective at maintaining articular surface reduction when used in combination with external fixation and K-wires and had a safety profile comparable to other forms of treatment.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10447175     DOI: 10.1053/jhsu.1999.0816

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  9 in total

Review 1.  [Tissue engineering of bone tissue. Principles and clinical applications].

Authors:  B Schmidt-Rohlfing; C Tzioupis; C L Menzel; H C Pape
Journal:  Unfallchirurg       Date:  2009-09       Impact factor: 1.000

2.  The use of beta-tricalcium phosphate bone graft substitute in dorsally plated, comminuted distal radius fractures.

Authors:  Michael G Jakubietz; Joerg G Gruenert; Rafael G Jakubietz
Journal:  J Orthop Surg Res       Date:  2011-05-22       Impact factor: 2.359

3.  Use of bone graft substitute in the treatment for distal radius fractures in elderly.

Authors:  Chintan Hegde; Vishvas Shetty; Sandeep Wasnik; Imthiaz Ahammed; Vijay Shetty
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-07-22

Review 4.  The use of bone grafts and substitutes in the treatment of distal radius fractures.

Authors:  Kagan Ozer; Kevin C Chung
Journal:  Hand Clin       Date:  2012-03-27       Impact factor: 1.907

Review 5.  Ceramic and non-ceramic hydroxyapatite as a bone graft material: a brief review.

Authors:  S R Dutta; D Passi; P Singh; A Bhuibhar
Journal:  Ir J Med Sci       Date:  2014-11-27       Impact factor: 1.568

6.  Volar plate fixation of intra-articular distal radius fractures: a retrospective study.

Authors:  Margaret W M Fok; Melissa A Klausmeyer; Diego L Fernandez; Jorge L Orbay; Alex Lluch Bergada
Journal:  J Wrist Surg       Date:  2013-08

7.  Evaluation of a novel nanocrystalline hydroxyapatite paste and a solid hydroxyapatite ceramic for the treatment of critical size bone defects (CSD) in rabbits.

Authors:  Franz-Xaver Huber; Irina Berger; Nicholas McArthur; Colette Huber; Hans-Peter Kock; Jürgen Hillmeier; Peter Jürgen Meeder
Journal:  J Mater Sci Mater Med       Date:  2007-06-14       Impact factor: 3.896

8.  [Mechanical failure of porous hydroxyapatite ceramics 7.5 years after implantation in the proximal tibial].

Authors:  W Linhart; D Briem; M Amling; J M Rueger; J Windolf
Journal:  Unfallchirurg       Date:  2004-02       Impact factor: 1.000

9.  Calcium phosphate cement augmentation after volar locking plating of distal radius fracture significantly increases stability.

Authors:  Hans Kainz; Enrico Dall'Ara; Anna Antoni; Heinz Redl; Philippe Zysset; Patrick Weninger
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-08-04
  9 in total