Literature DB >> 10447052

The non-invasive assessment of stroke volume and cardiac output by impedance cardiography: a review.

D G Newman1, R Callister.   

Abstract

Impedance cardiography (IC) is an inexpensive, reliable and noninvasive technique for determining stroke volume (SV) and cardiac output (CO). It relies on the measurement of phasic changes in transthoracic electrical resistivity, related to ejection of blood into the ascending aorta with each heart beat. Because of its non-invasive nature, IC is becoming increasingly used in clinical settings, as well as in many areas of physiological research. This paper discusses IC in terms of its theoretical basis, the components of the impedance signal and how impedance data is mathematically processed. One of the major controversies surrounding IC concerns how well it compares with conventional methods of determining SV and CO, such as thermodilution. A literature review of such comparative studies demonstrated that the controversy is far from settled, but that IC is generally agreed to be capable of accurately monitoring trends in cardiovascular dynamics. The question of accuracy of IC in terms of absolute values of SV and CO remains to be determined. The methodological limitations, accuracy, reliability and reproducibility of IC are examined, as are some of the methods developed to improve these aspects of the technique. The application and utility of IC in aerospace medicine research is also addressed.

Entities:  

Mesh:

Year:  1999        PMID: 10447052

Source DB:  PubMed          Journal:  Aviat Space Environ Med        ISSN: 0095-6562


  10 in total

1.  A novel approach to measure cardiac output noninvasively: a comparison with the thermodilution method on critical care patients.

Authors:  John Kabal; Bruce K Lagerman
Journal:  J Clin Monit Comput       Date:  2004-06       Impact factor: 2.502

2.  Descending aortic flow contribution to intrathoracic impedance-development and preliminary testing of a dual impedance model.

Authors:  A Barry Baker; Chris N McLeod; Alastair J Roxburgh; Paul Bannister
Journal:  J Clin Monit Comput       Date:  2007-11-15       Impact factor: 2.502

3.  Stroke volume equation for impedance cardiography.

Authors:  D P Bernstein; H J M Lemmens
Journal:  Med Biol Eng Comput       Date:  2005-07       Impact factor: 2.602

4.  Acetylcholinesterase inhibition: a novel approach in the treatment of neurogenic orthostatic hypotension.

Authors:  W Singer; T L Opfer-Gehrking; B R McPhee; M J Hilz; A E Bharucha; P A Low
Journal:  J Neurol Neurosurg Psychiatry       Date:  2003-09       Impact factor: 10.154

5.  Tissue hemoglobin monitoring of progressive central hypovolemia in humans using broadband diffuse optical spectroscopy.

Authors:  Jangwoen Lee; Jae G Kim; Sari Mahon; Bruce J Tromberg; Kathy L Ryan; Victor A Convertino; Caroline A Rickards; Kathryn Osann; Matthew Brenner
Journal:  J Biomed Opt       Date:  2008 Nov-Dec       Impact factor: 3.170

6.  Quantification of the impaired cardiac output response to exercise in heart failure: application of a non-invasive device.

Authors:  Jonathan Myers; Pradeep Gujja; Suresh Neelagaru; Leon Hsu; Daniel Burkhoff
Journal:  J Sports Sci Med       Date:  2009-09-01       Impact factor: 2.988

7.  Validation of a computational platform for the analysis of the physiologic mechanisms of a human experimental model of hemorrhage.

Authors:  Richard L Summers; Kevin R Ward; Tarynn Witten; Victor A Convertino; Kathy L Ryan; Thomas G Coleman; Robert L Hester
Journal:  Resuscitation       Date:  2009-10-04       Impact factor: 5.262

8.  Noninvasive measurement of cardiac performance in recovery from exercise in heart failure patients.

Authors:  Jonathan N Myers; Pradeep Gujja; Suresh Neelagaru; Leon Hsu; Daniel Burkhoff
Journal:  Clinics (Sao Paulo)       Date:  2011       Impact factor: 2.365

9.  A hybrid approach for quantifying aortic valve stenosis using impedance cardiography and echocardiography.

Authors:  Yunis Daralammouri; Khubaib Ayoub; Najwan Badrieh; Bernward Lauer
Journal:  BMC Cardiovasc Disord       Date:  2016-01-22       Impact factor: 2.298

10.  The utility of impedance cardiography in hemodynamic monitoring of patients with sepsis.

Authors:  James Butz; Yizhi Shan; Andres Samayoa; Orlando C Kirton; Thai Vu
Journal:  Trauma Surg Acute Care Open       Date:  2019-10-28
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.