Literature DB >> 10446032

Economic evaluation of alternative indicators for screening for diabetes mellitus.

K Shirasaya1, M Miyakawa, K Yoshida, E Takahashi, N Shimada, T Kondo.   

Abstract

BACKGROUND: the optimal indicator for screening for diabetes mellitus without relying on fasting conditions was clarified.
METHODS: the subjects were 891 men ages 26 through 80 years (48.5 +/- 8.5). The objectives of this study were (1) to elucidate the efficacy of 1,5-anhydroglucitol (1,5-AG), glycosylated hemoglobin, and fructosamine (FRA) as screening tests for non-insulin-dependent diabetes mellitus (NIDDM) or for impaired glucose tolerance (IGT) and (2) to perform an economic evaluation for each indicator. The efficacy of each indicator was evaluated by drawing the receiver operating characteristic curves and calculating the areas under these curves (AUCs). An original model was developed for the pur pose of cost-effectiveness analysis.
RESULTS: each indicator was evaluated as a screening test for NIDDM alone and for both IGT and NIDDM. The AUCs of 1,5-AG and fasting plasma glucose were the largest in the case of the detection of NIDDM alone and the detection of both IGT and NIDDM, respectively. FRA was, however, the most cost-effective in Japan.
CONCLUSION: using equations, we indicated the equi librium points at which the cost-effectiveness ratios of each indicator intersected in order to generalize the results. By calculating the appropriate-actual ratios of costs for each indicator, we could ascertain the optimal indicator for each country. Copyright 1999 American Health Foundation and Academic Press.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10446032     DOI: 10.1006/pmed.1999.0506

Source DB:  PubMed          Journal:  Prev Med        ISSN: 0091-7435            Impact factor:   4.018


  3 in total

1.  A1C for screening and diagnosis of type 2 diabetes in routine clinical practice.

Authors:  Zhong X Lu; Karen Z Walker; Kerin O'Dea; Ken A Sikaris; Jonathan E Shaw
Journal:  Diabetes Care       Date:  2010-01-12       Impact factor: 17.152

2.  Serum 1,5-anhydroglucitol when used with fasting plasma glucose improves the efficiency of diabetes screening in a Chinese population.

Authors:  Lingwen Ying; Xingxing He; Xiaojing Ma; Yun Shen; Hang Su; Jiahui Peng; Yufei Wang; Yuqian Bao; Jian Zhou; Weiping Jia
Journal:  Sci Rep       Date:  2017-09-20       Impact factor: 4.379

3.  Rational diagnoses of diabetes: the comparison of 1,5-anhydroglucitol with other glycemic markers.

Authors:  Umit Yavuz Malkan; Gursel Gunes; Ahmet Corakci
Journal:  Springerplus       Date:  2015-10-09
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.