X-ray spectra estimation using attenuation measurements from 25 kVp to 18 MV.

R G Waggener1, M M Blough, J A Terry, D Chen, N E Lee, S Zhang, W D McDavid.   

Abstract

Attenuation measurements for primary x-ray spectra from 25 kVp to 18 MV were made using aluminum filters for all energies except for orthovoltage where copper filters were used. An iterative perturbation method, which utilized these measurements, was employed to derive the apparent x-ray spectrum. An initial spectrum or pre-spectrum was used to start the process. Each energy value of the pre-spectrum was perturbed positively and negatively, and an attenuation curve was calculated using the perturbed values. The value of x-rays in the given energy bin was chosen to minimize the difference between the measured and calculated transmission curves. The goal was to derive the minimum difference between the measured transmission curve and the calculated transmission curve using the derived x-ray spectrum. The method was found to yield useful information concerning the lower photon energy and the actual operating potential versus the nominal potential. Mammographic, diagnostic, orthovoltage, and megavoltage x-ray spectra up to 18 MV nominal were derived using this method. The method was validated using attenuation curves from published literature. The method was also validated using attenuation curves calculated from published spectra. The attenuation curves were then used to derive the x-ray spectra.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10435529     DOI: 10.1118/1.598622

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  10 in total

1.  Reconsideration of the Iwasaki-Waggener iterative perturbation method for reconstructing high-energy X-ray spectra.

Authors:  Akira Iwasaki; Shigenobu Kimura; Kohji Sutoh; Kazuo Kamimura; Makoto Sasamori; Morio Seino; Fumio Komai; Singo Terashima; Mamoru Kubota; Yuichiro Narita; Yoichiro Hosokawa; Masanori Miyazawa
Journal:  Radiol Phys Technol       Date:  2012-06-14

2.  Determination of radiotherapy X-ray spectra using a screen-film system.

Authors:  H M Garnica-Garza
Journal:  Med Biol Eng Comput       Date:  2008-09-09       Impact factor: 2.602

3.  A convolution/superposition method using primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance: comparison of calculated and measured 10-MV X-ray doses in thorax-like phantoms.

Authors:  Shigenobu Kimura; Kohji Sutoh; Kazuo Kamimura; Akira Iwasaki; Makoto Sasamori; Fumio Komai; Morio Seino; Singo Terashima; Mamoru Kubota; Junichi Hirota; Yoichiro Hosokawa
Journal:  Radiol Phys Technol       Date:  2011-06-22

4.  CT scanner x-ray spectrum estimation from transmission measurements.

Authors:  Xinhui Duan; Jia Wang; Lifeng Yu; Shuai Leng; Cynthia H McCollough
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

5.  Segmentation-free x-ray energy spectrum estimation for computed tomography using dual-energy material decomposition.

Authors:  Wei Zhao; Lei Xing; Qiude Zhang; Qingguo Xie; Tianye Niu
Journal:  J Med Imaging (Bellingham)       Date:  2017-06-30

6.  Dual-Energy Technique at Low Tube Voltages for Small Animal Imaging.

Authors:  Seungryong Cho; Emil Y Sidky; Junguo Bian; Xiaochuan Pan
Journal:  Tsinghua Sci Technol       Date:  2010-02       Impact factor: 2.016

7.  Estimating the spectrum in computed tomography via Kullback-Leibler divergence constrained optimization.

Authors:  Wooseok Ha; Emil Y Sidky; Rina Foygel Barber; Taly Gilat Schmidt; Xiaochuan Pan
Journal:  Med Phys       Date:  2018-12-13       Impact factor: 4.071

8.  Estimating the Product of the X-ray Spectrum and Quantum Detection Efficiency of a CT System and Its Application to Beam Hardening Correction.

Authors:  Joseph J Lifton; Andrew A Malcolm
Journal:  Sensors (Basel)       Date:  2021-05-10       Impact factor: 3.576

9.  A Monte Carlo Study of the Photon Spectrum due to the Different Materials Used in the Construction of Flattening Filters of LINAC.

Authors:  J S Estepa Jiménez; M Díaz Lagos; S A Martinez-Ovalle
Journal:  Comput Math Methods Med       Date:  2017-07-10       Impact factor: 2.238

10.  Cone-Beam CT image contrast and attenuation-map linearity improvement (CALI) for brain stereotactic radiosurgery procedures.

Authors:  SayedMasoud Hashemi; Christopher Huynh; Arjun Sahgal; William Y Song; Håkan Nordström; Markus Eriksson; James G Mainprize; Young Lee; Mark Ruschin
Journal:  J Appl Clin Med Phys       Date:  2018-10-19       Impact factor: 2.102

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.